© Jun 2020 3-2 GTJZ1412E&1414E&1412E Plus Operation Manual
SAFETY
ELECTRICAL SHOCK HAZARDS
• Always maintain a safe distance
from power lines and electrical
equipment in accordance with ap-
plicable government regulations
and see Table 3-1 , page 3-2.
• Consider platform movement,
wire swinging or drooping, be-
ware of strong winds or gusts,
and do not operate the machine
when there is lightning or heavy
rain.
• If the machine comes into contact
with live wires, keep away from
the machine. Personnel on the
ground or on the platform must
not touch or operate the machine
until the power is switched off.
• Do not use the machine as a
ground wire during welding and
polishing operations.
Table 3-1
Voltage
(Phase to Phase, kV)
Minimum Safe Distance
(m/ft)
0-50 3.05 (10)
50-200 4.60 (15)
200-350 6.10 (20)
350 -500 7.62 (25)
500 -750 10.67 (35)
750 -1000 13.725 (45)
TIPPING HAZARDS AND
RATED LOAD
Maximum rated load bearing capacity of the platform:
Table 3-2
GTJZ1412E
Retracting 227 kg(500 lb)
Extending: Stationary only 107 kg(235 lb)
Extending: Extension only 120 kg(265 lb)
GTJZ1414E
Retracting 227 kg(500 lb)
Extending: Stationary only 107 kg(235 lb)
Extending: Extension only 120 kg(265 lb)
1412E Plus
Retracting 350 kg(772 lb)
Extending: Stationary only 230 kg(507 lb)
Extending: Extension only 120kg(265 lb)