Content of the inspection:
Visual inspection of the outer parts of the instrument, its accessories, media supplies and cables to assure
that there are no obvious damages.
Check that the lid, the quick clamp, the cable glands or conduits are closed and tight
Check that the purge air supply is working and that hoses and pipes are tight (if applicable)
Clean the cover and the window
Content of the maintenance:
Removal of the S305 from the duct and clean the probe with a fabric or if necessary a brush.
If you have a Teflon coated probe avoid using any other tools than fabrics for cleaning. The
Teflon coating may break.
If the dust build up is impossible to remove, pull off the complete outer Teflon sleeve and
replace it with a new Teflon sleeve.
The black surface under the sleeve is a second layer of very fine Teflon, which represents the
actual protection am may not be scratched.
12 Troubleshooting
12.1 No output signal
Check that the power and signal wiring are connected correctly.
Check that there is power on.
Run the auto setup.
If the S303 or S304 is not giving an output signal after these checks, contact your local distributor.
12.2 No response after auto setup
Make sure that normal processes are going on during auto setup.
Check that the power and signal wiring are connected correctly.
If the S303 or S304 is not giving an output signal after these checks, contact your local distributor.