Ref : 26702 18 07/01/15
PART 5 : Saving the parameters
The ARIANE card uses a list of so-called work parameters to operate;
these parameters correspond to those which can be read and changed.
The configuration parameters: MSTO, MSTF, etc.
The operating values: FP-O, FF-O, etc.
The manufacturer parameters: Hidden in use
After the door’s operation has been adjusted, all these values may be
saved to a "save" list by the "SAVE" function so that this adjustment may
be restored at any time with the INIT function.
,,,
Multifunction relay no. 2 rMF2
Operator type tyPE
Cabin cell connected CELL
Glazed door Vitr
Motor dire ction Smot
Limit switches stops directio
FdC
Shock si gnal direction CHoC
Shock management mode ModE
Hold under open voltage Msto
Hold under close voltage MstF
Opening Cruise frequency FP-O
End Of Opening frequency FF-O
Opening Sabre frequency FS-O
,,,
IN xx
INIT
List N°1
List N°2
Work parameters Saved adjusted list
List N°3
List N°…
SAVE
TABLES OF STORED FACTORY VALUES USED VALUE TABLE SAVED SITE
CLASSIFIED BY DOOR TYPE CAN BE READ AND CHANGED PARAMETERS TABLE
To avoid an accidental backup, the "SAVE" instruction is only
accessible in manufacturer mode in the PINI configuration
parameter.
To go into manufacturer mode and make a save :
1. Switch off the card power and wait for the relays to break
2. Press and hold the
and " keys
3. Still holding the keys, switch power on again
4. When "FP-O" is displayed, release the keys. You are in manufacturer
mode
5. Scroll the parameters with up to PINI
6. Press
to validate the choice
7. To reach the SAVE function, press
8. To make a save, press
9.
Simultaneously press and to confirm the save