Ref : 26702 31 07/01/15
To return to the parameter list, press .
TESTS AND ADJUSTEMENT TO DO
Reprogram card parameters following paragraph with title
« On-site replacement of an ARIANE card » page 21
Erase memory following indications page 37 and check if
faulty operation appears again.
Check U1. and U2. Voltage parameters and decrease them.
Check winding, wiring (court-circuit)
Check U1. and U2. Voltage parameters and decrease them.
Check winding, wiring (court-circuit)
Check U1. and U2. Voltage parameters and decrease them.
See problems met : "the door doesn’t see the encoder
anymore”
Check the 3 windings balance. Check the motor’s wiring.
Ramener la tension secteur à 220 V thanks to a
transformateur
Increase deceleration times
Reduce mains power voltage to 220 V à l'aide d'un
transformer
Erase memory : faults stored, following § instruction and
check if fault appears again
Select asynchronous motor in parameters
Reload parameters tables INxx
Corresponding to the door type controlled
(see § Notice: configuration following door type)
CAUSES
Memory Fault
Connector disconnected in the unit
Ventilation fault or parametering fault
Motor fault
Parametering fault
Motor fault
Parametering fault
Faulty encoder
Faulty motor
Faulty motor wiring
Mains power voltage superior to 270V
For heavy doors equipped with brushless motor
If deceleration time is too short
Mains power voltage inferior to 155 v
Hard and soft incompatibles
If brushless motor selected in parameters and
asynchronous motor installed.
Parameters do not correspond to the type of door
used
PROBLEMS MET
Err1 memory fault
Err2 (Mute power card)
Err3 (Excessive temperature)
Err4 (Overcurrent)
Err5 (Overload)
Err6 (Motor or encoder fault)
Err7 (Mains power supply over-voltage)
Err8 ( Mains power supply undervoltage)
Err9 ( Logical and power card incompatibles)
Err10 (Hall effect sensor fault)
*** Comment : generally speaking, when a
door is operating abnormally , check, first, if
the parameters loaded suit the door type
controlled.