SMA Solar Technology AG Technical Data
Installation Guide SMC9-11TLRP-IEN100640 83
General data
EC Declaration of Conformity Enclosed documentation package
Download area www.SMA.de/en
Dimensions (W x H x D) 468 mm x 613 mm x 242 mm (approx.)
Weight approx. 35 kg
Protection rating in accordance with
DIN EN 60529
IP65
Climatic conditions according to DIN EN 50178:1998-04:
Location of type C: Class 4K4H
Extended temperature range:
-25 °C to +60 °C
Extended humidity range:
0 ... 100 %
Extended air pressure range:
70 kPa to 106 kPa
Transport of type E: class 2K3
Temperature range:
– 25 °C ... +70 °C
Operation temperature range – 25 °C ... +60 °C
Max. operating altitude 3000 m above mean sea level
Topology Transformerless
Fan connection
Designed for safe disconnection in accordance with
DIN EN 50178:1998-04
Protection class I
Noise emission (typical) 42 dB(A) 45 dB(A) 46 dB(A)
Protective function DC side
All-pole disconnection unit on the DC input side Electronic Solar Switch,
DC plug system SUNCLIX
Overvoltage protection Thermally monitored varistors
Personnel protection Insulation monitoring (R
iso
> 1 M )
Pole confusion protection Via short-circuit diode
Protective function AC side
Short circuit proof Current control
SMC
9000TL-10
SMC
10000TL-10
SMC
11000TL-10