SMA Solar Technology AG 7 Commissioning
Installation Manual - Quick Reference Guide FSS-IS-en-42 27
7.3 Preparing BLUETOOTH Communication
To enable communication between SMA BLUETOOTH devices in the SMA Flexible Storage System, all devices must be
set to the same NetID (identification number for SMA Bluetooth network). The NetID is used to distinguish between
systems with SMA BLUETOOTH operating in close proximity to one another.
Procedure:
1. For PV inverters with integrated BLUETOOTH interface that communicate via Speedwire, set NetID 0 (see PV inverter
installation manual). This deactivates communication via BLUETOOTH.
2. Determine the NetID of the BLUETOOTH system:
Install Sunny Explorer on a computer. Either run the installation file on the CD provided or download free of
charge at www.SMA-Solar.com.
Determine a free NetID for the BLUETOOTH system using Sunny Explorer (see Sunny Explorer user manual).
Quit Sunny Explorer. This will ensure that the BLUETOOTH network is set up via the Sunny Home Manager.
3. Set the determined NetID on the Sunny Home Manager and on all devices with active BLUETOOTH interface
(see documentation of the BLUETOOTH devices). Note that the NetID must not be set to 1 if the
Sunny Home Manager is intended to communicate with more than one BLUETOOTH node.
7.4 Commissioning the SMA Flexible Storage System
Required data for registration in Sunny Portal:
Device / customer data Required data and explanation
Sunny Home Manager Serial number (PIC) and registration ID (RID)
Register the new system in Sunny Portal using the PIC and RID.
SMA Energy Meter Only when two SMA Energy Meters are installed, note down the serial number and
purpose (e.g., PV production meter) in each case. This way you can identify the
energy meters in the Sunny Portal.
PV inverters System password
The PV system password is the same as the device password for the user group
"Installer". All devices in a PV system must be set to the same password (for user
groups and security concept, see the Sunny Explorer user manual).
The default password is 1111.
Serial number of the PV inverters
You can uniquely identify the PV inverters in Sunny Portal using the serial number.
PV array power in kWp
SMA Radio-Controlled
Socket
The serial number and connected load of each SMA radio-controlled socket
In Sunny Portal, configure the SMA radio-controlled socket in accordance with the
requirements of the connected load. To do so, you require the serial number of the
SMA radio-controlled socket.