5 Starting and Stopping the Off-Grid System SMA Solar Technology AG
40 SI80H-BE-BEN120810 Operating Manual
5.6 Setting Time-Controlled Inverter Operation
Requirement:
The Sunny Remote Control must be in user mode (see Section 4.3).
1. Select the Inverter display page and press the
button.
The Sunny Remote Control switches to the
Inverter setting page.
2. Setting time-controlled inverter operation:
Select the Start Date parameter and set it to the required start date.
Select the Start Time parameter and set it to the required start time.
Select the Run Time parameter and set it to the required run time.
Select the Repetition parameter and set it to the required repetition cycle.
3. To activate time-controlled inverter operation, select the Timed Start parameter and set it to
Enable.
Time-controlled inverter operation is activated. If the off-grid inverter has started automatically
under time-control and you stop the off-grid inverter, time-controlled inverter operation is
deactivated automatically.
Example: Setting parameters for time-controlled inverter operation
You want to operate the off-grid inverter in inverter mode every Sunday from 10:00 am to 6:00 pm,
starting Sunday, 8 January 2012. To do so, set the off-grid inverter as follows:
Str.Date: 08.01.2012
Start Time: 10:00:00
Run Time: 08:00:00
Repetition: Weekly