19
EFE 2500A /AF - 4000A/AS/AN
8. MACHINES WITH AIR-COOLED CONDENSER
Figure 8 Figure 9
The freezer requires a minimum of 200 mm of clearance on both sides and
500 mm in the rear of the unit. (Figure 8-9)
The clearance will allow sufficient amount of air flow across the condenser. Failure to allow
adequate clearance can reduce the refrigeration capacity of the freezers and cause
permanent damage to the compressors.
Position the machine for easy accessibility for cleaning, servicing and maintenance. A
clean environment is also essential for the proper performance of the freezer.
Attention: The freezer must not be exposed to direct sunlight. If it
stands in direct sunlight the performance will decrease. As the air
temperature increases the performance decreases. This is true for all
refrigeration equipment.