6.3.5 CLR TOTL
CLR TOTL is used to clear and reset the total run time for
each zone shown in the TOTL RUN menu.
From the CLR TOTL menu, press NEXT and the display will
show KEEP. If you want to clear the TOTL RUN time and reset
the accumulation date, press either the or arrow button
to display CLEAR. With CLEAR showing in the display, either
press NEXT or BACK or turn the dial to complete the clearing
and resetting. This feature will stop accumulations on a zone
after 255 hours of cumulative zone run time.
6.3.6 CLR DEF
To clear deficits, press NEXT. Use or arrow buttons to select
KEEP or CLEAR. Press NEXT or BACK to exit CLEAR DEFICITS.
6.4 RAIN DLY
The rain delay feature allows user to globally suspend watering
operations for all programs for a selected number of days in
either the Standard or Auto Adjust watering modes.
Use and arrow buttons to select 1 to 7 days for watering
suspension. The watering blackout will automatically be cleared
from the SmartLine
®
controller after the assigned days have
expired and watering will resume at the next available start
time. Auto Adjust watering deficits will reset at zero and will
not resume accumulation until the delay has ended.
6.5 RUN/SOAK
The purpose of Run/Soak is to break up long run times that
often cause wasteful runoff. The Run/Soak is programmable for
each program if you are using the Standard watering mode.
Note: If you are using Auto Adjust, these inputs are not used
since the Run/Soak period is automatically calculated.
Use NEXT button to access RUN time allowed before the zone
watering pauses for the specified soak time. Use PGM button to
select program. Use and arrow buttons to set RUN time
from OFF to 30 minutes (SmartLine
®
controller default is OFF).
Use NEXT button to access soak time required for water to infil-
trate into soil before zone watering is continued. Use the
and arrow buttons to set soak time from 1 minute to 2 hours
in one-minute increments.
6.6 ZN:ZN DLY
This function allows user to
set delay times between zone
starts for use in systems with
slow closing valves or pump
systems that are operating
near maximum flow or have
slow well recovery. Use
and arrow buttons to
change value. Adjustable in
one-minute increments from 0
(the SmartLine
®
controller
®
6.0 Advanced Functions
19
Note: The
Master
Valve/Pump Start
circuit will operate during
the first 5 seconds of any
programmed delay to aid
in closing of the valve and
to avoid unnecessary
cycling of the pump. The 5
second period is program-
mable in the MV:ZN DLY
setting. (See Section 6.7)