1: Remote control (IP Address X switch set to 000)
The mode to respond to the following commands of the BOOTP/DHCP Server, supplied by Rockwell Automation.
Enable DHCP
The IP address etc. can be obtained from the BOOTP/DHCP Server. If the power supply is switched off and on again in this state,
the SI unit will obtain the IP address etc. again.
Disable BOOTP/DHCP
The IP address etc. cannot be obtained from the BOOTP/DHCP Server. If the power supply is switched off and on again in this
state, the previous settings will be maintained.
2: DHCP mode (IP Address X switch set to 255)
The mode to obtain the IP address from the DHCP server. The IP address will be lost when the power supply is turned off.
3: Manual setting of IP address
Manual setting of the IP address within the range 192.168.0.1 to 254, or 192.168.1.1 to 254.
Default setting
The default settings are "Remote Control" and "Enable DHCP" mode.
Note
•If the IP address of an SI unit is not known, set the mode to “DHCP mode” to reset the settings.