EasyManua.ls Logo

SMC Networks PF2M7 Series

Default Icon
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Digital
IP40
2-color
LED display
2-color
LCD display
NPN/PNP
open collector
Accumulated pulse output
Analog voltage output
Analog current output
Hysteresis mode: Variable
Window comparator mode:
Variable
±1% F.S.
(Fluid: Dry air)
Dry air, N2
12 to 24 VDC
±10%
[Monitor unit 3-color LCD display]
2 to 200
L/min
5 to 500 L/min
10 to 1000 L/min
20 to 2000 L/min
Digital
3-color LCD display
NPN/PNP
open collector
Accumulated pulse output
Analog voltage output
Analog current output
Hysteresis mode: Variable
Window comparator mode:
Variable
±1% F.S.
(Fluid: Dry air)
Dry air, N2
IP65
[Monitor unit IP40]
12 to 24 VDC
±10%
PFMC
5 to 500 L/min
10 to 1000 L/min
20 to 2000 L/min
Monitor unit
±0.1% F.S.
Monitor unit
±0.1% F.S.
PFG300
Flow Switch Variations / Basic Performance Table
The monitor unit values are for the PFG300 and PFMV3.
Fluid Series
PF2A
Dry air,
N
2, Ar, CO2
Setting
Digital Digital
Enclosure
IP40
Display
2-color LCD display
Output
NPN/PNP
open collector
Accumulated pulse output
Analog voltage output
Analog current output
Hysteresis
Hysteresis mode: Variable
Window comparator mode:
Variable
Hysteresis mode: Variable
Window comparator mode:
Variable
Repeatability
±1% F.S. ±1 digit
(Fluid: Dry air)
Power supply
voltage
Rated flow range
0.01 to 1 L/min
0.02 to 2 L/min
0.05 to 5 L/min
0.1 to 10 L/min
0.3 to 25 L/min
0.5 to 50 L/min
1 to 100 L/min
PFMV
Air, N2
IP65
LED display
NPN/PNP
open collector
Accumulated pulse output
Hysteresis mode: Variable
Window comparator mode:
Fixed (3 digits)
±1% F.S.
(PF2A70)
±2% F.S.
(PF2A71)
12 to 24 VDC
±10%
1 to 10 L/min
5 to 50 L/min
10 to 100 L/min
20 to 200 L/min
50 to 500 L/min
Digital
IP40
[Monitor unit 2-color LCD display]
NPN/PNP
open collector
Analog voltage output
Analog current output
±1% F.S.
(Fluid: Dry air)
Analog output:
±5% F.S.
Monitor unit
±0.1% F.S.
Analog output:
±0.5% F.S.
12 to 24 VDC
±10%
0 to 0.5 L/min −0.5 to 0.5 L/min
0 to 1 L/min −1 to 1 L/min
0 to 3 L/min −3 to 3 L/min
Dry air, N2
PF3A7H
Digital
Air, N
2
IP65
[Monitor unit IP40]
3-color LCD display
NPN/PNP
open collector
Accumulated pulse output
Analog voltage output
Analog current output
Hysteresis mode: Variable
Window comparator mode:
Variable
±1% F.S.
24 VDC ±10%
30 to 3000 L/min
60 to 6000 L/min
120 to 12000 L/min
Monitor unit
±0.1% F.S.
PFMV3 PFG300
Temperature characteristics
(25°C standard)
PF2M7(-L)
PFMB
PFG300
±2% F.S.
(15 to 35°C)
±5% F.S.
(0 to 50°C)
±2% F.S.
(15 to 35°C)
±5% F.S.
(0 to 50°C)
Monitor unit
±0.5% F.S.
(0 to 50°C)
Monitor unit
±0.5% F.S.
(0 to 50°C)
±3% F.S. (15 to 35°C)
±5% F.S. (0 to 50°C)
±2% F.S.
(15 to 35°C)
±5% F.S.
(0 to 50°C)
Monitor unit
±0.5% F.S.
(0 to 50°C)
±5% F.S.
(0 to 50°C)
Monitor unit
±0.5% F.S.
(0 to 50°C)
±3% F.S. ±1 digit
(15 to 35°C)
±5% F.S. ±1 digit
(0 to 50°C)
12 to 24 VDC
±10%
18 to 30 VDC
±10%
PF2M7
PF2M7-L
6

Other manuals for SMC Networks PF2M7 Series

Related product manuals