SMC Networks PFA Series - PFA Digital Flow Switch for Air; PFA7 Integrated Display Type

Default Icon
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
How to order
PFA7 10 01 27
Nil
N
Wiring specification
3m lead wire with connector
Without lead wire
10
50
11
21
51
Flow rate range
1 to 10l/min
5 to 50l/min
10 to 100
l/min
20 to 200l/min
50 to 500l/min
Symbol
01
02
03
04
Port size
1/8
1/4
3/8
1/2
10
50
100
200
500
Size
Applicable model
Flow rate (l/min)
Nil
27
28
67
68
Output specification
Output specification
NPN open collector 2 outputs
NPN open collector 1 output + Analog output (1 to 5V)
PNP open collector 2 outputs
PNP open collector 1 output + Analog output (1 to 5V)
Applicable model
Nil
M
Nil
N
F
Thread type
Unit specification
Rc
NPT
G
PFA710, 750
PFA711, 721, 751
PFA711, 721, 751
PFA710, 750
PFA711, 721, 751
PFA711, 721, 751
PFA710, 750
PFA711, 721
PFA751
Integrated
display type
For Air
1 to 10l/min 5 to 50l/min
Specifications
Note 1) For the type with unit switching function [The type without the unit switching function will have a fixed SI unit (l/min or l).]
Note 2) The output functions operate only for the real-time flow rate display, and do not operate for the accumulated flow display.
Note 3) Window comparator mode Since hysteresis is 3 digits, separate P1 and P2 by 7 digits or more. 1 digit is the minimum setting unit (refer to the table above).
Note 4) The flow rate unit is based on 0˚C and 101.3kPa.
PFA710 PFA750 PFA711 PFA721 PFA751
Model
Measured fluid
Detection type
Flow rate measurement range
Minimum setting unit
Operating pressure range
Withstand pressure
Pressure loss
Accumulated flow range
Operating temperature range
Linearity
Repeatability
Temperature characteristics
Output
specifications
Indicator lights
Response time
Hysteresis
Power supply voltage
Current consumption
Withstand voltage
Insulation resistance
Noise resistance
Vibration resistance
Impact resistance
Weight
Enclosure
Port size (Rc, NPT, G)
Display units
Note 1)
±1% F.S. or less
1/8, 1/4
Dry air, N
Heater type
10 to 100
l/min
1% of maximum flow rate
l, ft³
x 10
-
¹
0 to 0.5MPa
1.0MPa
3kPa (at 100
l/min)
0 to 999999l
0 to 50°C (with no condensation)
± 5% F.S. or less
±3% F.S. or less (15 to 35°C), ±5% F.S. or less (0 to 50°C)
1s or less
Hysteresis mode: Variable (can be set from 0), Window comparator mode: Fixed (3 digits)
12 to 24VDC (ripple ±10% or less)
1000VAC for 1 min. between external terminal block and case
50M (500VDC) between external terminal block and case
1000Vp-p, Pulse width 1µs, Rise time 1ns
10 to 500Hz at the smaller of amplitude 1.5mm or acceleration 98m/s² in X, Y, Z directions, 2 hours each
490m/s² in X, Y, Z directions, 3 times each
Equivalent to IP65
NPN open collector
PNP open collector
3kPa (at 50
l/min)
150mA or less
250g (without lead wire)
3/8
1/2
Real-time flow rate
Accumulated flow
l/min, CFM x 10
-
²
27, 67: Lights up when ON, OUT1: Green, OUT2: Red
––
27, 67: Lights up when ON, OUT1: Green, OUT2: Red
28, 68: Lights up when ON, OUT1: Green, OUT2: None
Output voltage: 1 to 5V
Load impedance: 100k or more
Maximum load current: 80mA, Internal voltage drop: 1V or less (with load current of 80mA)
Maximum applied voltage: 30V
Maximum load current: 80mA
Internal voltage drop: 1.5V or less (with load current of 80mA)
10kPa (at 200
l/min)
30kPa (at 500
l/min)
±2% F.S. or less
20 to 200
l/min
l/min, CFM x 10
-
¹
50 to 500
l/min
290g (without lead wire)
160mA or less
170mA or less
Switch
output
Analog
output
With unit switching function
Fixed SI unit
Note)
Note 2)
Note 3)
Note) Fixed units:
Real-time flow rate:
l/min
Accumulated flow:
l
1
Digital Flow Switch
Series PFA
For Air

Related product manuals