How to Order
PFA3
Remote Type
Display Unit
00A
A
B
Mounting
Panel mount
DIN rail, wall mount
0
1
Flow rate range
10, 50l/min
100, 200, 500
l/min
Nil
0
1
2
3
Output specification
Output specification
NPN open collector 2 outputs
PNP open collector 2 outputs
NPN open collector 1 output + Analog output (1 to 5V)
PNP open collector 1 output + Analog output (1 to 5V)
Applicable model
PFA30, 31
PFA31
Specifications
l/min, CFM x 10
-
²
Model
Flow rate measurement
range
Minimum setting unit
Accumulated flow range
Operating temperature range
Linearity
Repeatability
Response time
Hysteresis
Power supply voltage
Current consumption
Enclosure
Weight
Temperature
characteristics
Output
Specifications
Display
units
PFA301PFA300
Note 1) The flow rate measurement range can change depending on the setting.
Note 2) For the type with unit switching function [The type without the unit switching function will have a fixed SI unit (l/min or l).]
Note 3) The system accuracy when combined with sensor unit.
Note 4) The output functions operate only for the real-time flow rate display, and do not operate for the accumulated flow display.
Note 5) Window comparator mode –– Since hysteresis is 3 digits, separate P1 and P2 by 7 digits or more. 1 digit is the minimum setting unit (refer to the table above).
Note 6) The flow rate unit is based on 0°C and 101.3kPa.
1% of maximum flow rate
l, ft³
x 10
-
¹
0 to 999999
l
0 to 50°C (with no condensation)
±5% F.S. or less
l/min, CFM x 10
-
¹
10 to 100l/min, 20 to 200l/min
50 to 500
l/min
1 to 10, 5 to 50l/min
Lights up when On, OUT1: Green, OUT2: Red
––
Lights up when ON, OUT1: Green, OUT2: None
60mA or less
Equivalent to IP40
45g
1s or less
Hysteresis mode: Variable (can be set from 0), Window comparator mode: Fixed (3 digits)
Note 4)
12 to 24VDC (ripple ±10% or less)
Indicator lights
50mA or less
PFA310 PFA311 PFA312 PFA313
±1% F.S. or less (15 to 35°C)
±2% F.S. or less (0 to 50°C)
Lights up when ON, OUT1: Green, OUT2: Red
±1% F.S. or less
±1% F.S. or less
Note 3)
Switch
output
Analog
output
NPN open collector
PNP open collector
Maximum load current: 80mA
Maximum applied voltage: 30V
Internal voltage drop: 1V or less (with load current of 80mA)
Maximum load current: 80mA
Internal voltage drop: 1.5V or less (with load current of 80mA)
Output voltage: 1 to 5V
Load impedance: 100kΩ or more
Nil
M
With unit switching function
Unit specification
∗ PFA302 and 303 combinations are not available.
Fixed SI unit
Note)
Note) Fixed units:
Real-time flow rate:
l/min
Accumulated flow:
l
Note 1)
Note 2)
Real-time flow rate
Accumulated flow
Note 3)
Note 4)