EasyManua.ls Logo

Snap-On MIG225Ai - Arc Control Settings

Snap-On MIG225Ai
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
ADVANCED SETTING cont'd
Inductance
Adjustment can vary from -9.9 to +9.9. Factory setting
is zero. If the gure is negative, the impedance drops
and the arc becomes harder, while if it increases, the
arc is softer.
To access this function, simply highlight it using the
knob
B
and press it for less than 2 seconds. The
display screen
A
shows the adjustment bar. The
gure can be changed and conrmed by pressing the
knob
B
for less than 2 seconds.
AUTO burnback
The adjustment can vary from -9.9 to +9.9. Its purpose
is to adjust the length of the wire coming out of the gas
nozzle after welding. A positive gure corresponds to
greater wire burning.
Default is Auto (preset function). To access this
function, simply highlight it using the knob
B
and
press it for less than 2 seconds. The display screen
A
shows the adjustment bar. The gure can be changed
and conrmed by pressing the knob
B
for less than
2 seconds.
Soft Start AUTO
Adjustment can vary from 0 to 100%. This is the wire
speed expressed in percentage of the speed set
for welding, before the wire touches the piece to be
welded.
This adjustment is important to always obtain good
starts.
Default is Auto (preset function).
To access this function, simply highlight it using the
knob
B
and press it for less than 2 seconds. The
display screen
A
shows the adjustment bar. The
gure can be changed and conrmed by pressing the
knob
B
for less than 2 seconds.
.
Pre Gas
The adjustment can vary from 0 to 10 seconds.
To access this function, simply highlight it using the
knob
B
and press it for less than 2 seconds. The
display screen
A
shows the adjustment bar. The
gure can be changed and conrmed by pressing the
knob
B
for less than 2 seconds.

Other manuals for Snap-On MIG225Ai