9
Note: To select a stored PSET or manual target torque or angle mode, repeatedly press ENTER
buttonuntil desired PSET or manual mode is displayed.
Adding an Angle Preset
1. From target angle screen, press and hold UNITS U button for 3 seconds.
2. ADD PRESET confirmation screen is displayed. Highlight YES menu selection using UP S /DOWN
T buttons then press ENTER button. NO menu selection returns to main menu without adding
a PSET.
3. MINIMUM ANGLE screen is displayed. MINIMUM ANGLE is target value at which green progress
lights, audible alert and vibrator turn on. Initial MINIMUM ANGLE value is value from target angle
screen. MINIMUM ANGLE can be set from 0 to 360° by pressing UP S /DOWN T buttons. Once
desired target angle value has been set, press ENTER button.
4. MAXIMUM ANGLE screen is displayed next. MAXIMUM ANGLE is angle value above which red
progress lights turn on. Initial MAXIMUM ANGLE value will be MINIMUM ANGLE plus 4%.
Maximum angle value can be set to any value greater than MINIMUM ANGLE by pressing
UP S /DOWN T buttons. Once desired value has been set, press ENTER button.
5. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press
UP S /DOWN T buttons to increment/decrement batch count. Mode Count increments each
time target angle is reached if a batch count of zero is entered. Mode Count decrements if a non-
zero batch count is entered and resets to batch count value when count reaches zero. Once
desired value has been set, press ENTER button.
6. PSET target screen is displayed labeled with next available PSET number from 01 to 10.
7. To enter additional angle presets, repeatedly press ENTER button until target angle screen is
displayed and repeat steps above.
BATCH COUNT
ADD PRESET
YES
ADD PRESET
YES
NO
FT-LB
MINIMUM TORQUE
FT-LB
MAXIMUM TORQUE
FT-LB
FT-LB
BATCH COUNT
ADD PRESET
YES
ADD PRESET
YES
MINIMUM ANGLE
MAXIMUM ANGLE