Chapter 12 – Troubleshooting
S2646E/S3246E – 0410051 47
Symptom
Hydraulic fluid temperature of
160°F (71°C) or more.
Severe hydraulic leak.
Possible Cause
Prolonged driving or platform operation.
High pressure fluid return to reservoir
caused by kinked or twisted hose.
Hydraulic system component failure.
Failure of hose, tube, fitting, seal, etc.
Corrective Action
Stop operation until fluid cools.
Remove the kink or twist from the
hose. Let fluid cool before resuming
operation.
Stow the machine and do not oper-
ate until repairs are made.
Stow the machine and do not oper-
ate until repairs are made.