4.
For LP operation:
Completely open the valve (see Figure
11.18) on top of the LP tank (unscrew
counterclockwise until it stops).
5.
For a dual-fuel engine:
On the Lower Control Box:
Set the FUEL switch (not shown here) to
gasoline or LP gas depending on which you
want to use.
6. Enter the platform and close the gate.
Figure 11.20
7.
Turn the Emergency Stop switch
clockwise and it will pop out (on) (see Figure
11.20).
8. If the engine is cold, press and hold the
Choke switch (see Figure 11.20) during
the next step.
9.
Press and hold the Start switch down until
the engine starts or for 20 seconds,
whichever comes first. When the engine
starts, release both the start switch and
the choke switch (see Figure 11.20).
If the engine does not start in 20 seconds,
release the start switch and release the
Choke switch then wait 60 seconds before
trying to start the engine again.
n
RCD / ELCB Outlet
Figure 11.21- RCD / ELCB Outlet
The RCD (Re sid ual Cur rent De vice) is lo cated at
the ground and will pro tect against short cir cuits to
earth. When there is a short cir cuit the RCD will
shut down the 230v AC power to the plat form
outlet.
To re set the out let dis con nect the power tool lead
from the plat form box and re set the RCD at the
ground.
If the prob lem per sists call a trained ser vice tech ni -
cian.
n
Fall Restraint Lanyard Anchor Points
(option)
There are four (4) Fall Re straint an chor points on
the floor of the plat form for the S3970RT/S3370RT,
two (2) be hind the roll-out deck when re tracted, two
(2) be hind the roll-out deck when ex tended. For the
S2770RT there are an ad di tional two (2) be hind the
roll-out deck when re tracted.
The Fall Restraint Anchor points are rated
for Fall Restraint only. A Fall Arrest System
must not be attached. Death or serious
injury could result from use of a Fall Arrest
System.
The an chor points are po si tioned such that a Fall
Re straint Lan yard can be set short enough to pre -
vent the op er a tor reach ing the fall haz ard (when
not all guard rails are in place) while still al low ing
some free dom of move ment.
page 11 - 6 Rev A S3970RT, S3370RT & S2770RT – 13865-1
11. Options