Inverter states includes: wait, check, normal, fault and permanent
Wait:Inverter is waiting to Check State when reconnect the system. In this
state, grid voltage value is between the max and min limits and so on; If not,
Inverter will go to Fault State or Permanent State.
Check: Inverter is checking isolation resistor, relays, and other safety
requirements. It also does self-test to ensure inverter software and hardware are
well functional. Inverter will go to Fault State or Permanent State if any error or
fault occurs.
Normal:Inverter enter to Normal State,it is feeding power to the grid;
inverter will go to Fault State or Permanent state if any error or fault occurs.
Fault:Fault State: Inverter has encountered recoverable error. It should
recover if the errors disappear. If Fault State continues; please check the inverter
according error code.
Permanent:Inverter has encountered unrecoverable error, we need
maintainer debug this kind of error according to error code.