Press “up” or “down” to change the 1
st
digit, press “ok” to switch to next digit. Input the value of Discharge Depth &
EPS Discharge Depth per battery specification. Press “OK”.
For example: if Discharge Depth = 50% & EPS Discharge Depth = 80%.
While grid is connected: HYD-ES inverter won’t discharge the battery when its SOC is less than 50%.
In case of blackout: HYD-ES inverter will work in EPS mode (if EPS mode is enabled) & keep discharging the battery till
battery SOC is less than 20%.
4) Max. Charge (A)
Select “4. Max. Charge (A)” and press “OK”. Press “up” or “down” to change the 1
st
digit, press “ok” to switch to next
digit. Input the value of Max. Charge (A) per battery specification. Press “OK”.
5) *Over (V) Protection (only for DEFAULT battery type)
Select “5. Over (V) Protection” and press “OK. Press “up” or “down” to change the 1
st
digit, press “ok” to switch to
next digit. Input the value of Over (V) Protection per battery specification. Press “OK”.
6) *Max. Charge (V) (only for DEFAULT battery type)
Select “6. Max. Charge (V)” and press “OK”. Press “up” or “down” to change the 1st digit, press “ok” to switch to next
digit. Input the value of Max. Charge (V) per battery specification. Press “OK”.
7) Max. Discharge (A)
Select “7. Max. Discharge (A)” and press “OK”. Press “up” or “down” to change the 1
st
digit, press “ok” to switch to
next digit. Input the value of Max. Discharge (A) per battery specification. Press “OK”.
8) *Low (V) Protection (only for DEFAULT battery type)
Select “8. Low (V) Protection” and press “OK”. Press “up” or “down” to change the 1
st
digit, press “ok” to switch to
next digit. Input the value of Low (V) Protection per battery specification. Press “OK”.
9) *Min. Discharge (V) (only for DEFAULT battery type)
Select “9. Min. Discharge (V)” and press “OK”. Press “up” or “down” to change the 1
st
digit, press “ok” to switch to
next digit. Input the value of Min. Discharge (V) per battery specification. Press “OK”.
10) * Empty Discharged (V) (only for DEFAULT battery type)
Select “10. Empty Discharged (V)” and press “OK”. Press “up” or “down” to change the 1
st
digit, press “ok” to switch
to next digit. Input the value of Empty Discharged Voltage per battery specification. Press “OK”.