Sokkia SET530R/R3 Specifications

General IconGeneral
TypeTotal Station
Accuracy±(2 mm + 2 ppm)
Laser PointerYes
Waterproof/DustproofYes
Operating Temperature Range-20 °C to +50 °C
DisplayLCD
Angle Accuracy2"
Distance Range with Reflector3, 000 m

Summary

1. Precautions for Safe Operation

2. Precautions

3. Laser Safety Information

4. Set Functions

4.1 Parts of the Instrument

Identifies and labels all external components of the SET instrument.

5. Basic Operation

5.1 Basic Key Operation

Explains fundamental key operations on the instrument panel and wireless keyboard.

6. Using the Battery

6.1 Battery Charging

Provides a step-by-step procedure for charging the instrument's battery.

6.2 Installing / Removing the Battery

Guides on how to safely install and remove the instrument's battery.

7. Setting Up the Instrument

7.1 Centering

Details the process of positioning the instrument precisely over the surveying point.

7.2 Levelling

Explains how to level the instrument using circular and plate levels.

10. Angle Measurement

11. Distance Measurement

12. Coordinate Measurement

12.1 Entering Instrument Station Data

Steps to input instrument station coordinates, height, and target height.

12.3 3-D Coordinate Measurement

Calculating target's 3D coordinates using station and backsight settings.

13. Resection Measurement

13.1 Coordinate Resection Measurement

Determining instrument station coordinates using known point measurements (NEZ).

13.2 Height Resection Measurement

Determining instrument station height using known point measurements.

14. Setting-Out Measurement

14.1 Distance Setting-out Measurement

Setting out points based on horizontal angle and distance from a reference.

14.2 Coordinates Setting-out Measurement

Setting out points using coordinate data and horizontal angle/distance.

15. Setting-Out Line

15.1 Defining Baseline

Procedure for establishing a baseline by inputting coordinates of two points.

16. Point Projection

16.1 Defining Baseline

Procedure for establishing a baseline for point projection.

16.2 Point Projection

Projecting points onto a defined baseline and calculating distances.

17. Offset Measurement

18. Missing Line Measurement

22. Registering/Deleting Data

22.1 Registering/Deleting Known Point Data

Managing known point coordinate data via key entry or external instrument.

24. Changing the Settings

24.1 Changing Instrument Options

Adjusting EDM settings and other configuration parameters.

24.2 Allocating Key Functions

Customizing softkey allocations for efficient instrument operation.

25. Warning and Error Messages

26. Checks and Adjustments

28. Specifications