SE2200 SE3000 SE3500 SE4000
SE4000-
16A
SE5000 SE6000 Unit
Emissions
IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12,
FCC part 15 class B
RoHS Yes
Installation Specifications
AC output Cable Gland - diameter 9-16 mm
DC input
(1)
1 MC4 pair 2 MC4 pairs
Dimensions (W x L x
H)
540 x 315 x 172 540 x 315 x 191 mm
Weight 20.2 21.7 kg
Cooling Natural Convection
Noise (typical) < 50 dBA
Operating
temperature range
(2)
-20 - +50 (M40 version -40 to + 50) °C
Maximum altitude 2000 m
Operating humidity –
non condensing
< 95 %
Protection Rating /
Environmental
category
IP65 – Outdoor and Indoor
Pollution degree
classification (inside
/ outside)
2/3
Bracket mounted (bracket provided)
(1)
Connection of additional strings in parallel to a single input is allowed as long as the cumulative current does not
exceed 45A.
(2)
For inverter power derating refer to the application note at the following link:
http://www.solaredge.com/files/pdfs/se-temperature-derating-note.pdf
-Three Phase System Installation Guide MAN-01-00057-4.1
104 Technical Specifications - Single Phase Inverters (Europe &APAC)