SE4K SE5K SE7K SE8K SE9K SE10K SE12.5K Unit
Noise (typical)
< 50
(1)
dBA
Protection rating/
Environmental
category
IP65 - Outdoor and indoor
Maximum altitude 2000 m
Pollution degree
classification
(inside/outside)
2/3
Bracket mounted (bracket provided)
SE15K - SE33.3K
(2)
SE15K SE16K SE17K SE25K SE27.6K SE33.3K Unit
Output
Rated AC power
output
15000 16000 17000
25000
(3)
27600 33300 VA
Maximum AC power
output
15000 16000 17000 25000
6
27600 33300 VA
AC output voltage
line to line / line to
neutral (nominal)
380/ 220; 400/ 230 480/277 Vac
AC output voltage
range
184 264.5 244-305 Vac
AC frequency 50/60 ± 5 Hz
Maximum continuous
output current (per
phase)
23 25.5 26 38 40
40
@277V
A
Maximum continuous
overcurrent
protection
23 25.5 26 38 40 40 A
(1)
For inverters with a noise level suitable for residential environments refer to:
http://www.solaredge.com/files/pdfs/products/inverters/se-three-phase-indoor-inverter-
datasheet.pdf
(2)
The SE33.3Kmodel requires a medium voltage transformer.
(3)
24.99kVA in the UK
-Three Phase System Installation Guide MAN-01-00057-4.1
108Technical Specifications - Three Phase Inverters (Europe &APAC)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE3000 and is the answer not in the manual?

SolarEdge SE3000 Specifications

General IconGeneral
ModelSE3000
ManufacturerSolarEdge
AC Output Power3000 W
CoolingNatural Convection
Protection RatingIP65
Rated AC Power3000 W
Max. AC Power3000 VA
Maximum Output Current13 A
Number of MPP Trackers1
Operating Temperature Range-25°C to 60°C
AC Voltage230 V
Max. Input DC Voltage480 V