EasyManuals Logo

SolarEdge SE4000H User Manual

SolarEdge SE4000H
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
WARNING!
Before operating the inverter, ensure that the inverter AC power cable and wall
outlet are grounded properly. This product must be connected to a grounded,
metal, permanent wiring system, or an equipment-grounding conductor must
be run with the circuit conductors and connected to the equipment grounding
terminal or lead on the product.
WARNING!
Opening the inverter and repairing or testing under power must be performed
only by qualified service personnel familiar with this inverter.
WARNING!
Do not touch the PV panels or any rail system connected when the inverter
switch is ON, unless grounded.
WARNING!
SafeDC complies with IEC60947-3 when installing the system with a worst case
SafeDC voltage (under fault conditions) < 120V.
The worst case voltage is defined as: Voc,max+ (String Length-1)*1V, where:
Voc,max = Maximum Voc (at lowest temperature) of the PV modules in the
string (for a string with multiple modules, use the max value)
String Length = number of power optimizers in the string
CAUTION!
This unit must be operated according to the technical specification datasheet
provided with the unit.
CAUTION!
HEAVY OBJECT. To avoid muscle strain or back injury, use proper lifting
techniques, and if required - a lifting aid.
NOTE
Use PV modules rated according to IEC 61730 class A.
IMPORTANTSAFETYINSTRUCTIONS 7
EV Charging Single Phase Inverter Guide MAN-01-00583-1.5

Table of Contents

Other manuals for SolarEdge SE4000H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE4000H and is the answer not in the manual?

SolarEdge SE4000H Specifications

General IconGeneral
ModelSE4000H
ManufacturerSolarEdge
AC Output Power4000 W
Rated AC Power4000 W
Max. AC Power4000 VA
AC Voltage240 V
Max. Input DC Voltage480 Vdc
Dimensions26.2 x 15.4 x 8.3 in
Weight44.1 lbs
CoolingNatural Convection
Protection RatingIP65
AC Voltage Range211-264 V
Frequency60 Hz
Number of MPP Trackers1
Protection DegreeIP65
Max. Output Current16.7 A
MPPT Voltage Range380 - 480 Vdc
Max. DC Input Current15 A
Operating Temperature Range-25°C to 60°C
Maximum Efficiency99%
Max. Efficiency99%