EasyManuals Logo

SolarEdge SE5000 User Manual

SolarEdge SE5000
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
Figure 28: RS485 termination switch
NOTE
Only the first and last SolarEdge devices in the chain should be terminated.
The other inverters in the chain should have the termination switch OFF
(down position).
11. If not using surge protection, connect the grounding wire to the first inverter in the
RS485 chain; make sure the grounding wire is not in contact with other wires. For
inverters with a DC Safety Unit, connect the grounding wire to the grounding bus-
bar in the DC Safety Unit.
To connect to the monitoring platform:
1. Designate a single inverter as the connection point between the RS485 bus and the
SolarEdge monitoring platform. This inverter will serve as the master inverter.
2. Connect the master to the SolarEdge monitoring platform via the LAN or ZigBee or
cellular communication option.
3. Install an RS485 Plug-in in every EV Charging single phase inverter , refer to the
'Installing the RS485 Expansion Module' chapter in the RS485 Expansion Kit Installation
Guide and to configure the RS485 bus refer to the following sections.
To configure the RS485 communication bus:
All inverters are configured by default as slaves. If reconfiguration is required:
Chapter 7: Setting Up Communication 77
Three Phase System Installation Guide MAN-01-00057-4.1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE5000 and is the answer not in the manual?

SolarEdge SE5000 Specifications

General IconGeneral
ModelSE5000
ManufacturerSolarEdge
CategoryInverter
AC Output Power5000 W
Efficiency98.3%
CoolingNatural convection
Protection RatingIP65
Rated AC Power5000 W
Max. AC Power5000 VA
Maximum Input Voltage480 V
Number of MPP Trackers1
Max. Input DC Voltage480 V
Operating Temperature Range-25°C to 60°C
AC Voltage230 V