Status Screens - Operational Mode
Additionalpressesdisplaythefollowingscreensoneaftertheother.
Initial Status
V a c [ V ] V d c [ V ] P a c [ W ]
2 4 0 . 7 3 7 1 . 9 2 3 4 9 . 3
P _ O K : X X X / Y Y Y < S _ O K >
- - - - - - - - - - - - - - - - O N
l Vac [V]:TheACoutputvoltage
l Vdc [V]:TheDCinputvoltage
l Pac [W]:TheACoutputpower
Main Inverter Status
V a c [ V ] V d c [ V ] P a c [ W ]
2 4 0 . 7 3 7 1 . 9 3 2 1 0 . 0
F a c [ H z ] O P s _ O k T e m p
5 0 . 0 1 1 2 8 . 2
l Vac [V]:TheACoutputvoltage.
l Vdc [V]:TheDCinputvoltage.
l Pac [W]:TheACoutputpower.
l Fac [Hz]:TheACoutputfrequency.
l OPs_Ok:Numberofoptimizerssendingtelemetries(indicatingthattheyarepaired)
l Temp [C or F]:Theinverterheatsinktemperature
Energy Meter Status
Displaysthetotalenergyproducedduringthelastday,month,yearandsinceinverterinstallation.
D a y [ W h ] : 0 . 0
M o n t h [ K W h ] : 0 . 0
Y e a r [ K W h ] : 0 . 0
T o t a l [ K W h ] : 0 . 0
l Day:sincemidnight
l Month:since1stofthecurrentmonthuntiltoday(inclusive)
l Year:sinceJanuary1stuntiltoday(inclusive)
Ifameter(RGM)isconnectedtotheinverter,thefollowingstatusscreen,showingthepowerandenergy
readings,isdisplayedinadditiontotheabovescreen.
IfthemeterissettoExport+Import,therearetwostatusscreens,withthefirstlinedisplaying:"Export
Meter"or"ImportMeter".Thefollowingisanexampleofanexportmeterstatus:
E x p o r t M e t e r
S t a t u s : < O K / E r r o r # >
P o w e r [ W ] : x x x x x . x
E n e r g y [ W h ] : X X X X X . X