EasyManua.ls Logo

SolarEdge SE7600A-US - Connection Unit Leds

SolarEdge SE7600A-US
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connection Unit LEDs
TherearethreeLEDsonthelowerboardoftheConnectionUnit,neartheDIPswitches:
Figure 44: Connection Unit LEDs
l Innormaloperation,themiddleandbottomLEDsindicateauxiliaryvoltages(13VfromDC/DC,5Vand
3.3V)andshouldalwaysbelit.
l ThetopLEDshouldbelitwhentheinverterDCvoltageisatleast200Vdc(checkwhenbothinverter
ON/OFFswitchandConnectionUnitswitchareON).YoucancheckthestatusscreenfortheVdc
value.
l IfallLEDsareOFF:
o
CheckthatACvoltageexistsintheinverter
o
CheckthatthecommunicationcablebetweentheConnectionUnitandthedigitalboardis
properlyconnected.
l IfthetopLEDisON,andmiddleandbottomLEDsareoff-aninternalfailurehasoccurred.Contact
SolarEdgesupport.
Appendix A: Troubleshooting
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3
97