4. Technical Data
4.1 DC Input
Max. PV array input power [Wp]
Max. PV voltage [d.c.V]
Startup voltage [d.c.V]
Nominal input voltage [d.c.V]
MPPT voltage range [d.c.V]
No. of MPP trackers/Strings per MPP tracker
Max. PV current(input A/input B) [d.c.A]
I PV array Short Circuit Current(input
SC
A/input B) [d.c.A]
6000
600
50
360
40-560
6600
600
50
360
40-560
7200
600
50
360
40-560
8000
600
50
360
40-560
10000
600
50
360
40-560
4.2 AC Output
Max. output apparent power [VA]
Max. Output Continuous Current
[a.c.A]
14
15
Introduction Technical Data
Model
Nominal grid frequency/Grid frequency range [Hz]
12000
600
50
360
40-560
Rated Output Apparent Power [VA]
3000 3300 3680 4200 5000
26.1
Power factor range
16
13.1
14.4
Rated output current [a.c.A]
18.3
21.7
6000
3
X1-
BOOST-
3K-G4
X1-
BOOST-
3.3K-G4
X1-
BOOST-
3.6K-G4
X1-
BOOST-
4.2K-G4
X1-
BOOST-
5K-G4
X1-
BOOST-
6K-G4
2/1
16/16
22/22
Model
X1-
BOOST-
3K-G4
X1-
BOOST-
3.3K-G4
X1-
BOOST-
3.6K-G4
X1-
BOOST-
4.2K-G4
X1-
BOOST-
5K-G4
X1-
BOOST-
6K-G4
THDi (rated power) [%]
3300
14.4
3630
15.8
4620
20.1
5000
21.7
6000
220/230/240; 90-290
50/60; ±5
0.8leading-0.8lagging
<3
4048
17.6
27.3
4.3 Protection
Safety & Protection
Over/under voltage protection
DC isolation protection
Monitoring ground fault protection
Grid protection
DC injection monitoring
Back feed current monitoring
Residual current detection
Anti-islanding protection
YES
YES
YES
YES
YES
YES
YES
YES
Model
X1-
BOOST-
3K-G4
X1-
BOOST-
3.3K-G4
X1-
BOOST-
3.6K-G4
X1-
BOOST-
4.2K-G4
X1-
BOOST-
5K-G4
X1-
BOOST-
6K-G4
Over temperature protection
SPD (DC/AC)
AFCI (Arc-Fault Circuit-Interrupter)
Safety
EMC
Grid monitoring
YES
II/II
Optional
EN/IEC62109-1/2
EN61000-6-1/2/3/4; EN61000-3-2/3/11/12;EN55011
IEC61727, EN50549, G98/G99, AS 4777.2, VDE4105,
CEI 0-21, VFR, PP DS, TOR
System data
Max. efficiency [%]
Euro. efficiency [%]
Standby consumption [W] @Night
Ingress protection
Max. operation altitude [m]
Humidity [%]
Typical noise emission [dB]
4000
0~100
Model
X1-
BOOST-
3K-G4
X1-
BOOST-
3.3K-G4
X1-
BOOST-
3.6K-G4
X1-
BOOST-
4.2K-G4
X1-
BOOST-
5K-G4
X1-
BOOST-
6K-G4
Dimensions(W×H×D) [mm]
Weight [kg]
Cooling concept
Communication interfaces
-30~70
404x274x146
11.5
98
98 98
98 98 98
97 97 97 97
97
97
3
-25~60
Nature cooling
11.5
11.5
11.5
11.5
11.5
4.4 System data
Grid voltage [V]/Grid range
Note:
1. 4048 (3680 For G98, TOR and PPDS 2. 17.6 (16 For G98, TOR and PPDS
3. 5000 (4600 for VDE4105); 4. 21.7 (20 for VDE4105).
5. 5000 (4600 for VDE4105); 6. 21.7 (20 for VDE4105).
Standard
X1-
BOOST-
2.5K-G4
6000
600
50
360
40-560
X1-
BOOST-
2.5K-G4
2500
10.9
2750
12
X1-
BOOST-
2.5K-G4
98
97
11.5
3
5
6
X1-
BOOST-
2.5K-G4
1
2
4
RS485/DRM/USB/Heat Pump, Optional: CT/Meter;
Optional monitoring dongle
Pocket WiFi/LAN/4G
Note:
1. For models with internal fan (optional), typical noise emission is 30 dB.
25
1
Max. inverter backfeed current to
the array [d.c.A]
0
Nominal AC Voltage [a.c.V]
220/230/240
Current (inrush) [a.c. A]
13.5
Maximum output fault current [a.c.A]
Maximum output overcurrent
protection [a.c.A]
59 (3 ms)
50
Operating Ambient Temperature
Range [°C]
Protective class
I