2.3 Explanation of Symbols
Symbols on the Inverter
Symbol Explanation
The inverter is working normally, when the blue light is on.
An error has occurred, when the red light is on.
Symbols on the Type Label
Symbol
Explanation
Safety Safety
CE mark.
RCM remark.
Danger of high voltages.
Danger to life due to high voltages in the inverter!
Danger.
Risk of electric shock!
Observe enclosed documentation.
TUV certification.
Compliant with UKCA standards.
This section gives an explanation of all the symbols shown on the inverter
and on the type label.
The inverter complies with the requirements of the applicable
CE guidelines.
Beware of hot surface.
The inverter can become hot during operation. Avoid contact
during operation.
The inverter can not be disposed together with the household
waste.
Disposal information can be found in the enclosed
documentation.
Do not operate this inverter until it is isolated from mains and
on-site PV generation suppliers.
2.4 EC Directives
This section describes the requirements of the European low voltage
regulations, including safety instructions and system licensing conditions,
the user must comply with these regulations when
installing, operating, and maintaining the inverter, otherwise personal injury
or death may occur, and the inverter will be damaged.
Please read the manual carefully when operating the inverter. If you do not
understand "Danger", "Warning", "Caution" and the description in the
manual, please contact the manufacturer or service agent before installing
and operating the inverter.
Make sure that the whole system complies with the requirements of EC
(2014/35/EU, 2014/30/EU, etc.) before starting the module (i.e. to start the
operation).
Standard of 2014/35/EU (LVD)
EN IEC 62109-1; EN IEC 62109-2
EN 62477-1
Standard of 2014/30/EU (EMC)
EN IEC 61000-6-1; EN IEC 61000-6-2;
EN IEC 61000-6-3; EN IEC 61000-6-4;
EN IEC 61000-3-2; EN 61000-3-3;
EN IEC 61000-3-11; EN 61000-3-12
EN 55011
The assembly shall be installed in accordance with the statutory wiring
rules. Install and configure the system in accordance with safety rules,
including the use of specified wiring methods. The installation of the
system can only be done by professional assemblers who are familiar with
safety requirements and EMC. The assembler shall ensure that the system
complies with the relevant national laws. The individual subassembly of the
system shall be interconnected by means of the wiring methods outlined in
national/international such as the national electric code (NFPA) No. 70 or
VDE regulation 4105.
Danger to life due to high voltage.
There is residual voltage in the inverter which needs 5 min to
discharge.
• Wait 5 min before you open the upper lid or the DC lid.