80
Troubleshooting
Decommissioning
81
WARNING!
• Before dismantling the inverter, please be sure to
disconnect the DC switch, and then unplug the PV and AC
cables, otherwise it will lead to an electric shock hazard.
• Do not touch any inner live parts until at least 10 minutes
after disconnecting the inverter from the utility grid and the
PV input.
8 Decommissioning
8.1 Dismantling the Inverter
• Turn off the AC and DC switches of the inverter system
• Wait for 5 minutes for de-energizing
• Disconnect the AC output and then the DC input, communication and
other cables
• Remove the inverter from the bracket
• Remove the bracket if necessary
8.2 Packaging
If possible, please pack the inverter with the original packaging.
If it is no longer available, you can also use an equivalent carton that meets
the following requirements.
· Suitable for loads more than 30 kg.
· With handle.
· Can be fully closed.
8.3 Storage and Transportation
Store the inverter in dry place where ambient temperatures are always
between -30 °C ~ +70 °C. Take care of the inverter during the storage and
transportation.
8.4 Disposal of the inverter
If the service life of our inverter expires, dispose of it according to the local
disposal rules for electrical equipment waste.
When the inverter or other related components need to be disposed. Have it
carried out according to local waste handling regulations. Please be sure to
deliver wasted inverters and packing materials to certain site, which can
assist relevant department to dispose and recycle.
9 Disclaimer
This limited warranty applies to products sold after date of 1st Jan 2022,
and sold through our company or authorized resellers. The defective
parts or units replaced under a warranty claim become our properties,
and must be returned to us or Authorized Cooperated Partners
(distributors) for inspection with the original or equivalent packaging.
The product is not covered by warranty in the following cases:
A.The product is out of the warranty period;
B.Product failure is not reported to us within one month of appearance;
C.Failed to comply with our installation manual or maintenance
instructions for the inverter or accessory;
D.Failed to comply with the safety rules and regulations in respect of the
inverter or accessory;
E.The inverter or accessory is damaged during transportation but the
claimant has signed the delivery receipt (which requests the claimant to
double check the outside & inside of the package and take pictures as
evidence before signing the delivery receipt);
F.The replaced products have not been returned to us or cooperated
partners (distributors) within 30 days;
G.The defect is caused by improper usage of the product or failure to
comply with the usage of the product for purposes other than those for
which the product was designed or intended;
H.The product is moved for any reason after it has been installed
(regardless of whether it has been reinstalled subsequently or moved
back to the same location) unless it is reinstalled at the same address by
a qualified installer who has provided a test report to our company.
I.The damage or defect is caused by lightning, flood, fire, power surge,
corrosion, pest damage, actions of a third-party, or any other force
majeure factors;
J.The damage or defect is caused by embedded or external software or