4.3 Efficiency, Safety and Protection
Inverter+BMU
98.0%
Cetification
Model
Max. efficiency
98.0% 98.0%
DC Switch
YES
YES
YES
YES
YES
YES
YES
Type II
Type II
YES
YES
YES
Safety & Protection
DC isolation protection
Monitoring ground
Grid protection
Over current protection
Over load protection
Anti-Islanding protection
DC Surge protection
AC Surge protection
Residual current detection
DC injection monitoring
Over heat protection
Self-consumption (night)
Isolation type
Protective Class
Operating temperature range
Operation relative humidity
Cooling
Altitude
Dimension [W/H/D] [mm]
Weight [kg]
Display
Communication interfaces
Safety
EMC
Standard warranty [year]
<10 W
EN 50549, AS4777, VDE4105, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530
Non-isolated
IP66
-25°C~+60°C (derating at +45°C)
0~100%RH
Forced air cooling
4000 m
985 × 660 × 327.5
83.3
LED indicator × 4, LCD (Optional)
RS485/External WiFi/4G modular (Optional)
IEC/EN 62109-1 and 62109-2 (EU)
IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61000-6-4
5years/10years (Optional)
Note: AC voltage and frequency ranges may vary depending on the specific state grid.
77
98.0%
fault protection
Inverter+BMU
Model
X3-FTH-80K
X3-FTH-100K
X3-FTH-110K
X3-FTH-120K
X3-FTH-136K-MV
X3-FTH-150K-MV
X3-FTH-125K
Inverter+BMU
98.6%
Model
Max. efficiency
98.6% 98.6% 98.6% 99.0% 99.0%
DC Switch
YES
YES
YES
YES
YES
YES
YES
Type II
Type II
YES
YES
YES
Safety & Protection
DC isolation protection
Monitoring ground
Grid protection
Over current protection
Over load protection
Anti-Islanding protection
DC Surge protection
AC Surge protection
Residual current detection
DC injection monitoring
Over heat protection
X3-FTH-80K
X3-FTH-100K
X3-FTH-110K
X3-FTH-120K
X3-FTH-136K-MV
X3-FTH-150K-MV
X3-FTH-125K
98.6%
fault protection
Ø Efficiency, safety and protection of 40k-70k inverter
X3-FTH-40K-LV
X3-FTH-50K-LV
X3-FTH-70K-LV
X3-FTH-60K-LV
Ø Efficiency, safety and protection of 80k-150k inverter
4.4 General Data
Cetification
Self-consumption (night)
Isolation type
Protective Class
Operating temperature range
Operation relative humidity
Cooling
Altitude
Dimension [W/H/D] [mm]
Weight [kg]
Display
Communication interfaces
Safety
EMC
Standard warranty [year]
<10 W
ABNT NBR 16149:2013, ABNT NBR 16150:2013, ABNT NBR IEC 62116: 2012, IEC 61727
Non-isolated
IP66
-25°C~+60°C (derating at +45°C)
0~100% RH
Smart cooling
4000 m (Derating at 3000)
985 × 660 × 327.5
LED indicator × 4, LCD (Optional)
RS485/External WiFi/4G modular (Optional)
IEC/EN 62109-1 and 62109-2 (EU)
IEC/EN 61000-6-3, IEC/EN 61000-6-4
5years/10years (Optional)
84 84
Inverter+BMU
Model
Ø General data of 40k-70k inverter
X3-FTH-40K-LV
X3-FTH-50K-LV
X3-FTH-70K-LV
X3-FTH-60K-LV
Ø General data of 80k-150k inverter
18
19
Technical Data Technical Data

Other manuals for SolaX Power X3-Forth

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolaX Power X3-Forth and is the answer not in the manual?

SolaX Power X3-Forth Specifications

General IconGeneral
BrandSolaX Power
ModelX3-Forth
CategoryInverter
LanguageEnglish

Related product manuals