(3) Safety
WARNING:
The operator must be aware of safety precautions to prevent physical injury.
Any pressure-containing device can explode, rupture, or discharge its contents
if it is over-pressurized. Take all necessary measures to avoid over--pressurization.
Operating, installing, or maintaining the unit in any way that is not covered in
this manual could cause death, serious personal injury, or damage to the
equipment. This includes any modification to the equipment or use of parts not
provided by Solidpump. If there is a question regarding the intended use of
the equipment, please contact an Solidpump representative before
proceeding.
This manual clearly identifies accepted methods for disassembling units.
These methods must be adhered to. Trapped liquid can rapidly expand and
result in a violent explosion and injury. Never apply heat to impellers,
propellers, or their retaining devices to aid in their removal.
Do not change the service application without the approval of an authorized
You must observe the instructions contained in this manual. Failure to do so
could result in physical injury, damage, or delays.
(4) User safety
General safety rules
These safety rules apply:
Always keep the work area clean.
Pay attention to the risks presented by gas and vapors in the work area.
Avoid all electrical dangers. Pay attention to the risks of electric shock or arc flash hazards.
Always bear in mind the risk of drowning, electrical accidents, and burn injuries.
NOTICE:
Never operate a unit unless safety devices are installed. Also see specific information
about safety devices in other chapters of this manual.
Electrical connections
Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local regulations. For more information about requirements,
see sections dealing specifically with electrical connections.
Hazardous liquids
The product is designed for use in liquids that can be hazardous to your health. Observe these
rules when you work with the product:
Make sure that all personnel who work with biologically hazardous liquids are vaccinated
against diseases to which they may be exposed.
Observe strict personal cleanliness.
Wash the skin and eyes
Follow these procedures for chemicals or hazardous fluids that have come into contact
with your eyes or your skin:
Condition Action
C hem i cal s o r
hazardous fluids
in eyes
1. Hold your eyelids apart forcibly with your fingers.
2.Rinse the eyes with eyewash or running water for at least 15minutes.
3. Seek medical attention.
C hem i cal s o r
hazardous fluids on
skin
1. Remove contaminated clothing.
2. Wash the skin with soap and water for at least 1 minute.
3. Seek medical attention, if necessary.
(5) Environmental safety
The work area
Always keep the station clean to avoid and/or discover emissions.
Waste and emissions regulations
Observe these safety regulations regarding waste and emissions:
Dispose appropriately of all waste.
Handle and dispose of the processed liquid in compliance with applicable environmental
regulations.
Clean up all spills in accordance with safety and environmental procedures.
Report all environmental emissions to the appropriate authorities.
Electrical installation
For electrical installation recycling requirements, consult your local electric utility.
Recycling guidelines
Always recycle according to the guidelines listed below:
Follow local laws and regulations regarding recycling if the unit or parts are accepted by
an authorized recycling company.
If the first guideline is not applicable, then return the unit or parts to the nearest
Solidpump representative.
2. Product description
(1) Pump design
FLUID TYPE/TEMPERATURE Work drainage and sand carrying/0 to 40
PUMP
IMPELLER Open
SHAFT SEAL
Double mechanical seal
BEARING
Sealed ball bearing
MOTOR
TYPE,POLES Dry type submersible induction motor 2poles
INSULATION Class F
MOTOR
PROTECTOR(BUILT-IN)
Circle thermal protector( 11kW)
Miniature protector Non-standard parts
LUBRICANT
Turbine oil VG32
DISCHARGE CONNECTION
Hose coupling
3 4