(5) TBZE technical data and function
NO Category Set Value
Actuation
Recovery
Recovery Mode s
1 phase loss
2
Manually recovery
(Manually turn off the
power ---- correct the
power --- turn on the
power, pump works
2 Impeller jam
Double rated
current
0.1
Manually recovery
(Manually turn off the
power ---- solve the
problem --- turn on the
power, pump works
3
Phase
sequence
protection
With power
line input
errors, the
work
Manually recovery
(Manually turn off the
power ---- switch the
input wire --- turn on the
power, pump works
4
Over-current
protection
1.2 times
rated current
30 300 Automatic recovery
5
Low-voltage
protection
323V 5 300 Automatic recovery
6
Overvoltage
protection
460V 5 300 Automatic recovery
7
Temperature
protection
Winding
0.1
Automatic recovery
(Winding 80±10
8
Water level
control
Stated
otherwise
Note: TBZE Metal head of electrode will be ON when touching the water, OFF when leaving water.
TBZE water-level control mode
a. When the pump is power on, if floating switch ( or water- t means the
pump starts to work.
b. In the running of the pump, if floating switch ( or water-
pumps will stop working after 60s continuous working, but if floating switch ( or water-level
-stop.
c. Stop time: After the pump stops for low water-level, it will not start within 60s ( even if
floating switch ( or water-level detector) is ON; unless plug in the power again after power off)
d. Recovery mode: The pump stops for low water-level, it will start automatically after 60s
when floating switch ( or water-level detector) is ON.
3. Prior to use
(1) Inspect the product
Inspect the package for damaged or missing items upon delivery.
rify that no damage has occurred during shipment and that
bolts and nuts have not loosened.
File a claim with the shipping company if anything is out of order.
NOTICE:
If the product has been picked up at a distributor, make a claim directly to the distributor.
(2) Inspect the specification
Check the nameplate of the pump unit to verify that it is the product that you have ordered. Pay
particular attention to its voltage and frequency specifications.
NOTICE:
If you discover any damage or discrepancy, please contact with the
Solidpump dealer from whom you purchased the product or the
nearest Solidpump representative office.
(3) Product specification
CAUTION:
Do not use the product under conditions other than those specified. Doing so
may lead to short, electrical shock, or fire, or might inhibit the product from
attaining its full potential.
(4) Method of starting
Direct-on-line start