EasyManuals Logo

SOLIS S6 Series Installation And Operation Manual

SOLIS S6 Series
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
6. Operation6. Operation
6.5.3 24H Switch
This function controls the 24H hours consumption function enable or disable.
Enable
Disable
Figure 6.19 Set 24H ON/OFF
NOTE:
When this is enabled, the inverter LCD will still be alive at night with
the power LED light on. If the grid is in malfunction at night, the system cant
recover even after the grid is back to normal but the consumption data will
still be recorded in the meter. Until the sunrise, the system will start to work
again while the meter data can be uploaded to the Solis monitoring system
to calibrate the load consumption data.
These two functions are applicable by maintenance personnel only, wrong
operation will prevent the inverter from working properly.
6.5.4 Clear Energy
Clear Energy can reset the history yield of inverter.
6.5.5 Reset Password
This function is used to set the new password for menu “Advanced info.” and “Advanced
information” (see Figure 6.20).
Figure 6.20 Set new password
YES=<ENT> NO=<ESC>
Password: 0000
Enter the right password before set new password. Press the DOWN key to move the cursor,
Press the UP key to revise the value. Press the ENTER key to execute the setting.
Press the ESC key to return to the previous menu.
6.5.7 Calibrate Energy
Maintenance or replacement could clear or cause a different value of total energy. Use this
function could allow user to revise the value of total energy to the same value as before. If
the monitoring website is used the data will be synchronous with this setting automatically.
Figure 6.21 Calibrate energy
YES=<ENT> NO=<ESC>
Energy:0000000kWh
Press the DOWN key to move the cursor, Press the UP key to revise the value. Press the
ENTER key to execute the setting. Press the ESC key to return to the previous menu.
6.5.8 Special Settings
This function is applicable by maintenance personnel only, wrong operation
will prevent the inverter from working properly.
6.5.6 Power control
Active and reactive power can be set through power setting button.
There are 5 item for this sub menu:
1. Set output power
2. Set Reactive Power
3. Out_P With Restore
4. Rea_P With Restore
5. Select PF Curve
This function is applicable by maintenance personnel only, wrong operation
will prevent the inverter from reaching maximum power.
.35..34.

Other manuals for SOLIS S6 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SOLIS S6 Series and is the answer not in the manual?

SOLIS S6 Series Specifications

General IconGeneral
Number of MPPTs2
THDi<3%
DC SwitchYes
Max. AC Output Power6000W
Rated AC Output Power6000W
Max. AC Apparent Power6000VA
Rated Grid Voltage230V
Grid Voltage Range180V-280V
Rated Grid Frequency50Hz/60Hz
Grid Frequency Range45-55Hz / 55-65Hz
ProtectionDC Reverse-Polarity Protection, AC Short-Circuit Protection
Operating Temperature Range-25°C to 60°C
CoolingNatural Cooling
CommunicationWiFi/GPRS

Related product manuals