8
EN
Copyright © 2014 - 2015 Somfy SAS. All rights reserved. Non contractual images.
2.4.2. Replacing a lost or broken Somfy io-homecontrol
®
control point
Apply the double cutout only for the end-product
to be reset.
This reset deletes all io-homecontrol
®
local
control points; however the sensors, end limit
settings and favourite position are retained.
1) Position the roller shutter at its half-way position.
2) Cut the power supply for 2 seconds.
3) Switch the power supply back on for 5 to
15 seconds.
4) Cut the power supply for 2 seconds.
5) Switch the power supply back on: the roller shutter
moves for a few seconds. (If the end product is in
the upper or lower end limit position it will move
6) Press the PROG button on the new io control
point until the roller shutter moves back and forth:
the new control point is programmed and all the
other io control points are deleted.
2.4.3. Deleting the end limit settings: return to default automatic mode
1) Position the roller shutter at its half-way position.
2) Simultaneously press and V, 5 s, until
there is back and forth movement by the roller
shutter.
3) Simultaneously press , my and V, 2 s,
until there is back and forth movement by the
roller shutter:
The end limit settings are deleted.
The control points, the sensors and the favourite
position (my) are still programmed.
- Resume the set-up operation (see Set-up section).
Apply the double cutout only for the end-product
to be reset.
This reset deletes all programmed control points,
all sensors, all end limit settings and resets the
favourite position (my) for the drive.
1) Position the roller shutter at its half-way position.
2) Cut the power supply for 2 seconds.
3) Switch the power supply back on for 5 to
15 seconds.
4) Cut the power supply for 2 seconds.
5) Switch the power supply back on: the roller shutter
moves for a few seconds.
6) Press the PROG button on the Somfy
io-homecontrol
®
control point for 7 s, until there
are two back and forth movements by the roller
shutter:
The drive is now reset to its factory
- Resume the set-up operation (see Set-up section).
6)
my
2 s
2 s
15 s
5 s
1)
5)
3)
2)
4)
OFF
OFF
ON
ON
1
5 S
2 S
1) 2)
3)
1
6)
PROG. 7 S
my
2 s
2 s
15 s
5 s
1)
5)
3)
2)
4)
OFF
OFF
ON
ON
X 2