EasyManuals Logo

Sontex 56 Series User Manual

Sontex 56 Series
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
24
Instruction for Use | HCA 56x and 8x8
6.2 The Digital Display
During normal operation the display is deactivated and can be activated by pushing the button.
If the button is not pushed, the display will be active for 2 minutes only. On request, the heat
cost allocator is also available with permanent display 24h/24h or with a rolling menu displayed.
Consumption Value Unit
Scale
002345
u
On the display of the heat cost allocator with unit scale an index
u for unit is shown on the left side. If the index u is not display-
ed, the heat cost allocator is equipped with the product scale.
Consumption Value Product
Scale
When commissioning the device this value is 000000. When
reaching the value 999999, the counting restarts automatically
at 000000.
Display in Euro
43.725
Eu
The heat cost allocators 6556/566/868 have the option to dis-
play the heating cost in Euro.
The cost in Euro indicated on the display is only approximate
and is based on historical values from the previous year.
The displayed cost does not necessarily represent the charges to
be paid.
Manufacturer and supplier decline any claims concer-
ning the use and interpretation of the indicated
values.
This option can be activated via the software Prog6.
Set day Value & Check code
002345
Sd
With the index Sd the consumption value recorded at mid-
night of the set day is displayed.
The consumption value recorded can be in unit scale or in
product scale. It’s depending of the unit setting.
000000
Sd
If a new device has not yet reached the programmed set day,
000000 is displayed.
54321
CC
With the index CC the check code for the plausibility check of
the manual readout is displayed.
Time
14h27
The current time (always winter time).
Date
29.05.15
The current date of the heat cost allocator.
Set day
29.05.--
SD
It is possible to program an annual set day on which the cumu-
lated consumption value as well as the maximal radiator tem-
perature are recorded.
With the index Sd the programmed annual set day is displayed.
002345

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sontex 56 Series and is the answer not in the manual?

Sontex 56 Series Specifications

General IconGeneral
BrandSontex
Model56 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals