EasyManuals Logo

Sontex Superstatic 789 User Manual

Sontex Superstatic 789
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
25
Instruction for use | Supercal 739
Qn Threaded
connection
*EAS
Mounting
length
*EAS
Mat PN Maximal
ow
qs
Minimal
ow
qi
Low ow
threshold
value
(50°C)
Threaded
hole for
sensor
Total
Meter
Weight
Kvs value
(20°C)
Pressure
loss at
qp
m
3
/h G'' DN mm bar m
3
/h l/h l/h Kg m
3
/h bar
(EN
ISO
228-1)
0.6 3/4 '' (15) 110 Brass 16 1.2 12 8 yes 0.6 1.7 0.08
1.5 3/4'' (15) 110 Brass 16 3.0 15 10 yes 0.6 3.4 0.19
1.5 1'' (20) 130 Brass 16 3.0 15 10 yes 0.6 3.4 0.19
2.5 1'' (20) 130 Brass 16 5.0 25 17 yes 0.7 5.9 0.18
13.2 Coaxial multi jet meter with G2'' connection
*EAS = base 16 bar = 1.6 MPa
Mounting
The Supercal 739 should not be mounted on the side where the continuous operating temperature of
the liquid exceeds 90°C or is below 5°C.
Length of straight section tted upstream/downstream of each ow meter (EN1434): U0 / D0 for:
L=110mm and L=130mm
qp1.5
qp0.6
qp2.5
0.01
0.1
1
0.1 1 10 100
Pressure loss [bar] ==>
Flow [m3/h] ==>
Pressure loss
Sontex Supercal 739
log-log
Pressure loss curve

Other manuals for Sontex Superstatic 789

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sontex Superstatic 789 and is the answer not in the manual?

Sontex Superstatic 789 Specifications

General IconGeneral
BrandSontex
ModelSuperstatic 789
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals