Perform
following
checks:
from
section
3-3-4
to
3-3-8,
after
attaching
the
top
cover.
(It
is
not
necessary
to
tighten
the
screws.)
3-3-4.
Frequency
Characteristics
Check
Connection
Audio
analyzer
(Level
meter)
Rear
panel
Procedure
(1)
Connect
the
audio
analyzer
(level
meter)
to
LINE
OUT
CH-1.
(2)
Play
back
the
second
track
(1
kHz,
0
dB
signal)
on
the
test
disc
(YEDS-18).
(3)
Set
the
audio
analyzer
so
that
its
level
(on
the
level
meter)
becomes
0
dB.
(4)
Play
back
the
following
track
on
the
test
disc
(YEDS-18)
and
check
that
the
playback
levels
satisfy
the
given
specification.
@
3rd
track
(20
Hz,
0
dB)
@
5th
track
(10
kHz,
0
dB)
@
6th
track
(20
kHz,
0
dB)
Specification:
Playback
level=0+0.5
dB
(5)
Connect
the
audio
analyzer
(level
meter)
to
LINE
OUT
CH-2.
(6)
Perform
steps
(2)
to
(4).
(Checking
CH-2)
CDP-3100
3-3-5.
De-emphasis
Frequency
Characteristics
Check
Connection
Same
as
3-3-4.
Procedure
:
(1)
Connect
the
audio
analyzer
(level
meter)
to
LINE
OUT
CH-1.
(2)
Play
back
the
second
track
(1
kHz,
0
dB
signal)
on
the
test
disc
(YEDS-18).
(3)
Set
the
audio
analyzer
so
that
its
level
(on
the
level
ā€˜meter)
becomes
0
dB.
(4)
Play
back
the
thirteenth
track
(16
kHz
with
emphasis)
on
the
test
disc
(YEDS-18)
and
check
that
the
playback
level
satisfies
the
following
specification.
-
Specification:
Playback
level
=
-9.04+0.5
dB
(5)
Connect
the
audio
analyzer
(level
meter)
to
LINE
OUT
CH-2.
(6)
Perform
steps
(2)
to
(4).
(Checking
CH-2)
3-3-6.
Distortion
Ratio
Check
Connection
Rear
panel
Distortion
analyzer
Procedure
(1)
Connect
the
audio
analyzer
(distortion
analyzer)
to
LINE
OUT
CH-1.
(2)
Play
back
the
following
track
on
the
test
disc
(YEDS-18)
and
check
that
the
distortion
ratios
satisfy
the
given
specification.
@
2nd
track
(1
kHz,
0
dB)
@
3rd
track
(20
Hz,
0
dB)
@
6th
track
(20
kHz,
0
dB)
Specification:
Distortion
ratio
=
0.01%
or
less
(3)
Connect
the
oscilloscope
to
LINE
OUT
CH-2.
(4)
Perform
steps
(2).
(Checking
CH-2)
3-5
(E)