Command List
FCB-EV7520A(GB) D-023-100-11(1)
33
VISCA Command/Acknowledge Protocol
Command Command Message Reply Message Comments
General Command 81 01 04 38 02 FF
(Example)
90 41 FF (Acknowledge)
+90 51 FF (Completion)
90 42 FF 90 52 FF
Returns Acknowledge when a command has been accepted, and
Completion when a command has been executed.
81 01 04 38 FF
(Example)
90 60 02 FF (Syntax Error) Accepted a command which is not supported or a command
lacking parameters.
81 01 04 38 02 FF
(Example)
90 60 03 FF
(Command Buffer Full)
There are two commands currently being executed, and the
command could not be accepted.
81 01 04 08 02 FF
(Example)
90 61 41 FF
(Command Not Executable)
90 62 41 FF
Could not execute the command in the current mode.
Inquiry Command 81 09 04 38 FF
(Example)
90 50 02 FF (Completion) Acknowledge is not returned for the inquiry command.
81 09 05 38 FF
(Example)
90 60 02 FF (Syntax Error) Accepted an incompatible command.
Address Set 88 30 01 FF 88 30 02 FF Returned the device address to +1.
IF_Clear(Broadcast) 88 01 00 01 FF 88 01 00 01 FF Returned the same command.
IF_Clear (For x) 8x 01 00 01 FF z0 50 FF (Completion) Acknowledge is not returned for this command.
Command Cancel 8x 2y FF z0 6y 04 FF
(Command Canceled)
Returned when the command of the socket specified is canceled.
Completion for the command canceled is not returned.
z0 6y 05 FF (No Socket)
Returned when the command of the specified socket has already
been completed or when the socket number specified is wrong.