39
Advanced Setup Table
Df = Factory Default Setting
Step# Description Pg# Range Df
35 3rd StageTurnoff Point 26 Deadband, Setpoint Deadband
36 4th Stage Turnoff Point 26 Deadband, Setpoint Deadband
37 Fan Program 27 On, Off Off
38 Minutes of Fan Runtime 27 0-60 0
39 Fan Program Start Time 27 12:00A - 12:00A 7:00A
40 Fan Program Stop Time 27 12:00A - 12:00A 9:00A
41 Wired Sensor Type 27 Remote, Supply Remote
42 Control to Temp Source 28 Thermostat, Wired Remote*, Thermostat
Wireless Remote, Average of
Wireless Remotes, Average
Thermostat and Wired Remote*,
Average All Sensors.
*Option only if prior step =
“Remote”
43 Wireless Remote to Use 28 list of wifi sensors currently first linked
linked to thermostat. sensor in
* This step only appears list
if prior step = “Wireless
Remote”
44 Fan Off Delay 27 0 - 120 Seconds 0
45 F/C 28 Fahrenheit (F), Celsius (C) F
46 Comfort Recovery 27 On, Off Off
47 Dry Contact Polarity 29 Open, Closed Open
48 Dry Contact Use 29 Condensate, Vacation, FDD Vacation
49 Skyport 29 On, Off On
50 Local API 29 On, Off Off
51 ADR 33 On, Off On
52 ADR Action 33 Observe Setpoint Offset, Observe set-
Observe Static Setpoints point offsets
53 Event Max Cool Setpoint 33 65 - 90 90
54 Event Min Heat Setpoint 33 50 - 85 50
55 Static Cool Setpoint 33 65 - 85 82
56 Static Heat Setpoint 33 65 - 85 60
57 Cool Setpoint Offset 34 1 to 10 4
58 Heat Setpoint Offset 34 -1 to -10 -4