EasyManua.ls Logo

Source 1 S1-THEM22P7S User Manual

Source 1 S1-THEM22P7S
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
O w n e r s M a n u a l
O w n e r s M a n u a l
HVAC SERVICE PARTS
TM
BACKLIT DISPLAY
Use with most
Heat Pump Systems:
2-Heat, 2-Cool
Model
COMMERCIAL
S1-THEM22P7S
Digital
Thermostat
Digital
Thermostat
Heat/Cool & Heat Pump
7-Day Programmable
Heat/Cool & Heat Pump
7-Day Programmable
Stages: 2-Heat, 2-Cool
Backlit Digital Display
Aux Heat Indicator
System Powered
Fahrenheit or Celsius
Auto-Changeover
of Power Failure
Clock Backup in the Event
Keypad Lockout
Up to 4 Hour Override
Question and Answer IconNeed help?

Do you have a question about the Source 1 S1-THEM22P7S and is the answer not in the manual?

Source 1 S1-THEM22P7S Specifications

General IconGeneral
Stages Heat2
Stages Cool1
Display TypeLCD
ProgrammableYes
Backlit DisplayYes
Hold FunctionYes
Battery LifeUp to 1 year
Programmability7-day
Power MethodHardwired
Power Source24VAC
Temperature Range45°F to 90°F

Summary

Safety Warnings

Location of Controls

Display Information

Display Mode Indicators

Explains indicators for heating, cooling, and auxiliary heat modes.

Display Time, Day, and Period Indicators

Shows current time, day, and active program period indicators.

Display Setpoint Information

Displays current room temperature and desired heating/cooling setpoints.

Display Status Indicators

Display Current Room Temperature

Shows the current ambient temperature reading on the display.

Display Operational Status Indicators

Indicates occupied periods, continuous fan, override, and keypad lock status.

Normal Operation

Manual Operation Mode

How to operate the thermostat manually, setting mode and temperature.

Programmed Operation Mode

How to run the thermostat using programmed schedules.

Clock Setting

Time Period Programming

Time Period Programming Overview

General explanation of how to enter and navigate time period programming screens.

Configuring Occupied Periods and Times

Setting occupied periods, setpoints, days, and start/stop times.

Program Management and Overrides

Copying programs, overriding schedules, and exiting programming mode.

Advanced Setup

Fan and Backlight Configuration

Configure fan operation mode and display backlight behavior.

Deadband and Setpoint Differential

Adjust deadband for stage activation and minimum setpoint difference.

Operating Parameters Configuration

Set cycles per hour, temperature units, and view system type settings.

Advanced Features Explained

Understanding Deadband and Setpoints

Detailed explanation of deadband operation and heat/cool differential.

Energy Saving Smart Fan Operation

How the smart fan feature optimizes energy use during occupied periods.

Keypad Lockout Functionality

Procedure to lock and unlock the thermostat keypad for security.

Factory Defaults

Calibration Procedure

Warranty Information

Related product manuals