1. Inadequate mix in hopper.
2. Improper mixing of product.
3. Torque arm is not installed correctly.
4. Viscosity adjustment is set incorrectly.
5. Le/right sensor not engaging and/or is
stuck to the le.
6. Up/down sensor is engaged and stuck in up
posion.
1. Ensure hopper is at least half full.
2. Follow manufacturer instrucons for mixing.
product; ensure correct mix raos.
3. Install torque arm on dispensing door.
4. Lower viscosity seng as required (Page 13).
5. Verify sensor arms are installed and
operang according to the manual
1. Improper mixing of product.
2. Missing, damaged, or incorrectly installed
scraper blades.
3. Viscosity adjustment is set incorrectly.
4. Beater is rotang counter-clockwise.
1. Follow manufacturer instrucons for mixing
product; ensure correct mix raos.
2. Inspect scraper blades for damage and correct
installaon.
3. Increase viscosity seng as required (Page 13).
4. Call Spaceman Technical Support.
1. Machine is unplugged.
2. Tripped circuit breaker or blown fuse.
3. Machine has tripped safety reset.
1. Verify machine is plugged into power source.
2. Verify and reset circuit breaker and/or fuse.
3. Reset machine (Page 13).
Machine has tripped safety reset due to motor
overload.
Reset machine (Page 13).
Check sensor arms.
1. Lubricaon on square ends of drive sha.
2. Scoring due to lack of lubricaon.
1. Do NOT lubricate the square end of the drive
sha; contact Spaceman Technical Support for
instrucons on removing and inspecng drive
sha and gear box for damage.
2. Replace Drive Sha, use addional lubricaon.