1. Product is over-frozen in cylinder.
2. Inadequate mix in hopper.
3. Power switch is in the OFF posion.
4. Unit is unplugged.
5. Tripped circuit breaker or blown fuse.
6. Improper mixing of product.
7. Machine has tripped safety reset.
8. Up down sensor arm not engaging
1. Lower viscosity seng as required (Page
13).
2. Ensure hopper is at least half full.
3. Turn power switch to FREEZE.
4. Verify machine is plugged into power
source.
5. Verify and reset circuit breaker and/or fuse.
6. Follow manufacturer instrucons for mixing
product; ensure correct mix raos.
7. Reset machine (Page 13).
8. Verify sensor arms are installed and
operang according to the manual.
1. Improper or inadequate lubricaon of drive
sha gasket.
2. Damaged, missing, or improperly installed drive
sha gasket.
3. Debris build up in back of cylinder
1. Use sucient food-grade lubricant, and add
sucient lubricant inside drive sha gasket
during assembly (Page 8).
2. Replace drive sha gasket every 1 to 3 months;
replace torque assembly guide every 1 to 3
months.
3. Clean back of cylinder well taking special note
around the lips of rear shell bearing connecon.
1. Improper or inadequate lubricaon of draw
valve and draw valve O-rings.
2. Cracked, broken, or worn draw valve O-rings.
1. Use sucient food-grade lubricant when
assembling draw valve (Page 8).
2. Replace O-rings every 1 to 3 months.
1. Broken torque or beater assembly.
2. Beater guide worn or missing.
3. Incorrect assembly of beater, blades, and guide
1. Repair or replace torque or beater assembly.
2. Replace or install beater guide.
3. Assemble machine to manual instrucons.
Cylinders are experiencing freeze-up (usually
due to viscosity being set too high for selected
product).
1. Reset machine (Page 13), conrm there is
product in the hopper, conrm there is no
blockage from hopper to cylinder.
2. Conrm product was premixed properly.
3. Lower viscosity as required (Page 13).