12
appears and the Automatic (A) symbols ash until self-leveling has been completed.
When the A symbols is solid, the laser starts rotating. See pic 5 for horizontal and pic 6
for vertical.
Pic 5 Standard display horizontal
Pic 6 Standard display vertical
Pressing and holding the E button (j) shows the actual rotation speed and the internal
product temperature. (Pic 7). This temperature can be dierent from the ambient
temperature.
Pic 7 E button info
Note: For HI-alert (shock warning) description and how to change, see chapter 18.1.
To turn O the laser, press and hold the power button for two seconds.
Note: If the laser is out of its self-leveling range and remains out of it for more than 10
minutes, the unit shuts down completely.
6 Menu Navigation
WHY: A menu driven interface can access all features of the GL1425C. This is an
intuitive way to operate the laser. It is easy to use since it does not require various two
or three nger button presses.
WHAT: Both the laser and the remote control RC1402 have a keypad for menu access.
The menu selections vary depending on horizontal or vertical setup.
HOW: Press M button (h) to enter the menu and to see a function in the menu or to
see a sub menu. Press E button (j) to start the function or to enter the submenu. Scroll
within the menu or submenu with the UP/DOWN arrow buttons (f). The selected
function is indicated by arrow brackets >> <<. An up or down arrow at the right side
indicates there are more features accessed by scrolling up or down. Press M button
(h) to go back to next level until the standard display is shown.
Menu functions when GL1425C set up in horizontal mode:
>>Grade<<
>>Rotation<<
>>GradeMatch<<
>>PlaneLok<<
>>Mask Mode<<