Questions and Answers

  • D
    debbiewilliamsJul 25, 2025
    How to troubleshoot a SPRIANO SST50 Transmitter that doesn’t turn on?
    • C
      carolynwhiteJul 25, 2025
      If your SPRIANO Transmitter doesn't turn on, there are several things to check: * **Supply Voltage:** Ensure the supply voltage is within the range of 12.5Vdc to 30Vdc. * **Polarity:** Verify that the transmitter connection polarity is correct. * **Electrical Load:** Make sure the electrical load is less than the maximum allowed.
  • B
    Brian MorrisJul 31, 2025
    Why is the SPRIANO Transmitter measure incorrect?
    • T
      Terry RamirezJul 31, 2025
      If the measure on your SPRIANO Transmitter is incorrect, consider the following: * **Process Compatibility:** Accurately verify the compatibility between the process and the connection type. * **Sensor Drift:** Apply zero input conditions to the transmitter and use the OFFSET command. * **EMC Interference:** Accurately verify the possible presence of electromagnetic interference on the supply line and check the PE connection.
  • J
    Jeffery BentonAug 7, 2025
    What to do if SPRIANO SST50 has erratic analog output?
    • C
      Charles CarrilloAug 7, 2025
      If the analog output of your SPRIANO Transmitter is erratic: 1. **Wrong Span Limits:** Correct the output using the LRV and URV command (or SET LRV and SET URV). 2. **Uncalibrated Analog Output:** Verify the analog output calibration using the LOOP TEST command. If it's incorrect, calibrate the output using the CAL4-20mA command. 3. **Incorrect HART® Settings:** Verify that the polling address is set to 0 using the ADDRESS command.
  • B
    Brandon VelasquezAug 13, 2025
    What causes analog output 20mA in SPRIANO Transmitter?
    • V
      vincent04Aug 13, 2025
      If the analog output of your SPRIANO Transmitter is less than 4mA or greater than 20mA: * **Transmitter in Fault Mode:** Check if the output is out of the allowed span or if there is a failure indicated on the display (e1, e2, etc.). * **Wrong Fault Settings:** Check the settings using the ALARM TYPE command.
  • P
    Pamela WigginsAug 19, 2025
    How to fix unstable measure on SPRIANO Transmitter?
    • B
      Brittany BowmanAug 19, 2025
      If you are experiencing an unstable measure with your SPRIANO Transmitter, it might be due to measuring disturbs. You can set an input average using the DAMP VALUE command (i.e. 10 seconds).

Summary

EU Declaration of Conformity

ATEX Directive Compliance

Compliance with ATEX Directive for explosive atmospheres.

PED Directive Compliance

Compliance with Pressure Equipment Directive for fluids.

INSTALLATION

Electrical Connection

Instructions for connecting the transmitter electrically.

OPERATIONS

Keyboard Configuration

Guide to configuring the transmitter using its keyboard.

MAINTENANCE AND TROUBLESHOOTING

Display Error Codes

List and description of error codes displayed by the transmitter.

DATA SHEET

Physical Characteristics

Key physical and electrical specifications of the transmitter.

Operative Conditions

Details on temperature, humidity, and power supply limits.

FUNCTIONAL SAFETY

IEC 61508; IEC 61511 Parameters

Safety parameters according to IEC 61508/61511 standards.

SPRIANO SST50 Specifications

General IconGeneral
BrandSPRIANO
ModelSST50
CategoryTransmitter
LanguageEnglish

Related product manuals