ASP 116 EVOLUTION INSTALLATION MANUAL
Sprinte SAS. All rights reserved , including translations.
41
Rollback settings
Choose « YES » to enable the rollback management
Increase the following 2 parameters in case of rollback on startup:
Choose « YES » . Do not change
Brake settings on stop.
Set the brake current injection’s time on stop.
Set the brake contactor closing’s delay.
For an open-loop asynchronous motor only: :
Set the brake closing frequency.
Decrease value whether a shock is felt or stop is done by the brake.
Increase value in case of rollback on stop (0,1Hz à 0,5Hz maxi)
FREQ. INVERTER
ROLLBACK MGT
ROLLBACK MGT
YES
ROLLBACK COMP.
40 %
RIGIDITY CTRL
YES
FREQ. INVERTER
ROLLBACK MGT
ROLLBACK DAMPING
70 %
FREQ. INVERTER
BRAKE
BRAKE ENGAGE TIM
0,50 s
BRAKE ENGAGE FCY
0,1 Hz
BRAKE
STOP ADJUST.
BRAKE ENGAGE DLY
0,50 s
-
-
-
BACK
-
-
-
ENTER
ENTER