VENTILATION, HEATING, AIR CONDITIONING AND AIR PURIFICATION SYSTEM
9-5
The DI engine equipped vehicle has the supplementary
heating devices to increase the heating effect before the
engine coolant is fully heated. The supplementary heating
devices are as follows:
-
PTC (Positive Temperature Coefficient)
SUPPLEMENTARY HEATING DEVICE
PTC (Positive Temperature Coefficient)
This supplementary heater is an electrical air heating type and
installed on the heater outlet port. This device improves the heating
effect by increasing the temperature of flowing air into the passen-
ger room.
This device is operational/non-operational when the engine control
unit supplies/cuts off the voltage to PTC according to the coolant
temperature and the ambient temperature.
X Operational Condition
This device is activated when the temperature switch is at any
position other than “OFF” position and the coolant temperature and
the ambient temperature is within a specified range.
X Non-operational Condition
- The temperature switch is at “OFF” position
- Defective ambient temperature sensor
- During engine cranking
- Too low battery voltage
- During pre-glowing process ( indicator ON)
A120_RHD_09_Air Conditioning System.p65 2006-10-02, ¿ÀÀü 11:06Page 5 Adobe PageMaker 6.5K/Win

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SSANGYONG STAVIC and is the answer not in the manual?

SSANGYONG STAVIC Specifications

General IconGeneral
BrandSSANGYONG
ModelSTAVIC
CategoryAutomobile
LanguageEnglish

Related product manuals