EasyManua.ls Logo

Stahl SLE22 - Signal Relays

Stahl SLE22
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 General description, function
16 10.20133
BA_SLE22_EN.DOCX
3.7.4 Signal relays
CAUTION
e
rr
a
nd
"
option
" are used for transmitting error signals and must not be used for safety
-
relevant functions.
The signal relays may only be parameterized by a skilled electrician using suitable tools.
Both relays can be parameterized as normally open or normally closed:
Rela
y
Normally open
Normally closed
option
S3_7 off
S3_7 on
err
S3_6 off
S3_6 on
Err switches at every error condition which interrupts a hoist motion.
Option can be parameterized as required. Parameterizing is dependent on the position
of switch S3.
DIP
switch
:
S
witch
S3_3
S
witch
S3_4
S
witch
S3_5
option relay
0
0
0
does not switch
1
0
0
switches at overload
0
1
0
at overtemperature
1
1
0
at sensor error
0
0
1
at all errors which
disable
lifting and lowering
1
0
1
wiping contact at overload: relay changes to
switching state for 500 ms
0
1
1
not used
1
1
1
not used
The settings are made during initial commissioning in
the factory.