TROUBLESHOOTING
THE
ELECTRICAL
SYSTEM
Disconnect
the
main
cable
connector
at
the
J1
position
of
the
relay
assembly
circuit
board.
Check
the
VDC
reading
at
the
silver
tabs
on
the
relay
assembly
circuit
board.
Tab
#4
(labelled
t/WHD
is
positive
and
tab
#5
(labelled
GND/BLK)
is
negative
(refer
to
Wiring
Diagram
2).
You
should
get
a
reading
between
15
and
17
VDC
. If
your
reading
is
not
within
the
range
,
replace
the
relay
assembly
circuit
board
and
retest.
c. If
you
are
getting
the
correct
voltage
at
tabs
#4
and
#5,
check
the
VDC
reading
at
the
connector
labelled
position
J1
on
the
relay
assembly
circuit
board.
Pin
#4
is
positive
and
pin
#5
is
negative
.
You
should
get
a
reading
between
15
and
17
VDC.
If
your
reading
is
not
within
the
range
,
replace
the
relay
assembly
circuit
board
and
retest.
5.
d. If
all
of
the
above
power
tests
produce
VDC
readings
that
are
within
range
and
the
Power
ind
i
cator
light
is
still
not
lit,
the
Power
indicator
light
is
probably
inoperable.
Replace
the
relay
assembly
circuit
board
and
retest.
Ensure
that
all
of
the
wires
you
disconnected
in
steps
5a-5c
are
securely
reconnected
.
Remove
the
console
and
disconnect
the
console
cable
.
Use
a
DC
voltmeter
to
measure
the
VDC
at
pin
#9
(positive)
and
pin
#1
(negative)
of
the
console
cable
connector
.
You
should
get
a
reading
between
15
and
17
VDC
. If
the
reading
is
not
within
the
range
,
replace
the
cable
assembly
and
retest.
6. If
the
problem
still
exists
,
contact
the
Customer
Serv
i
ce
Department
at
StairMast
er