15
STOVE DIMENSIONS
Note: Dimensions stated are in millimetres unless otherwise stated and may be subject to a slight +/- variation.
TECHNICAL DATA
Gas Type G20
I
2H
, I
2E
G20/G25
I
2E+
G20/G25
I
2ELL
G25
I
2L
Supply Pressure mbar 20 20/25 20 25
Nominal Heat Input Gross (Hs) kW 8.5 8.5/7.8 8.5/7.0 7.8
Nominal Heat Input Nett (Hi) kW 7.7 7.7/7.0 7.7/6.4 7.0
Consumption
m
3
/hr
0.796 0.796/0.850 0.796/0.761 0.850
Burner Pressure (hot) mbar 15.5 15.5/22.3 15.5/18.7 22.3
Maximum Heat Output kW 5.5
Minimum Heat Output kW 1.8
Injector Marking 320 (Front) / 280 (Rear)
Pilot 446.1385.44
Efficiency Class/Efficiency 2 / 81%
Nox Class 5
NATURAL GAS
LPG
Gas Type G30/G31
I
3B/P(30/50)
G30/G31
I
3+
G31
I
3P(37,50)
G31
I
3P(30)
Supply Pressure mbar 30/50 28-30/37 37/50 30
Nominal Heat Input Gross (Hs) kW 5.9 5.9 5.9 5.1
Nominal Heat Input Nett (Hi) kW 5.4 5.4 5.4 4.7
Consumption
m
3
/hr
0.167 0.167 0.206 0.186
Burner Pressure (hot) mbar 28.7 28.7 36.5 29.5
Maximum Heat Output kW 5.0
Minimum Heat Output kW 1.7
Injector Marking 100 (Rear)
Pilot 446.1385.24
Efficiency Class/Efficiency 2 / 83%
Nox Class 5