- 33 -
Symptom Cause Remedy Page
NOK, even if it sets
incorrect rivet
1. Judgement range setting is not
correct
Set judgement range correctly
P15, 16
2. Judgement range setting is too largel
P15, 16
3. Not fasten 5 rivets in average mode
Fasten 5 rivets, if it has an error,
do it again
P.15
4. There is a problem in tool.
Remove cause of issue or contact
local service center
-
5. Trigger module is defective.
assembly or contact local service
-
6. Smart function is turned off.
No NOK judgement if smart
function is turned off.
If needed, turn on smart function
P.14
show process curve
or does not show
1. Smart function is turned off.
P.14
2. Rivet break load is small, it is under
3,000N
Turn off smart function, if low
break load rivets are used
P.8, P14
correctly
(does not count or
counts even if it
does not set rivet).
1. Rivet break load is too small, it is
under 2,000N
Counter function cannot be used
in very low break load rivet.
P.8
2. Riveting cycle is too fast.
Pulled trigger before judgement.
Pull trigger for next riveting after
judgement.
-
4. Setting data are broken
Restore to factory settings
P31
low.
1. Smart function is turned on.
Rivets / Charge decreases, if
smart function is turned on. Turn
on/off smart function as needed.
P.14
2. Battery is not fully charged
Check battery charge level and
charge battery
Refer to
tool
-
*Contact Stanley Engineered Fastening local service center, if you cannot recover troubles from trouble shooting
above.
Others
“Manufacturer” in ”13. Others” menu is for administration in Stanley Engineered
Fastening”, so do not use this menu.